Original installation and operation manual
Illustration
For further information about fault indications during operation, see "15. Troubleshooting and fault repair / FAQ" on
Page 71.
n = ∞
BEKOMAT
Description / explanation
Discharge procedure (TEST button pressed briefly)
•
The red ALARM LED is off.
•
The green VALVE LED is on during the discharge
procedure.
•
The green POWER LED is on.
Pre-alarm (TEST button pressed >1 minute and
<5 minutes)
•
The red ALARM LED flashes.
•
The green VALVE LED is on.
•
The green POWER LED is on.
Alarm (TEST button pressed >5 minutes)
•
The red ALARM LED is on.
•
The green VALVE LED is off.
•
The green POWER LED is on.
Alarm mode (malfunctioning of condensate discharge)
•
The red ALARM LED flashes.
•
The green POWER LED is on.
•
The green VALVE LED is on when the solenoid valve is
cycling.
0 The solenoid valve is cycling every 4 minutes.
After the malfunction has been eliminated, the
BEKOMAT
automatically switches to normal operation.
®
12i / 12i CO / 12i CO PN63
®
49 | 76