BEKOMAT
®
12i / 12i CO / 12i CO PN63
12.2 Decommissioning work
Illustration
X2
X3
66 | 76
X2
X3
Original installation and operation manual
Description / explanation
1. Interrupt the condensate feed via the condensate inlet
line [X2] (e.g. by closing the recommended shut-off
valve [X3]).
2. Press the TEST button briefly multiple times.
0 The pressure in the BEKOMAT
0 The condensate remaining in the BEKOMAT
drained.
3. Disconnect the BEKOMAT
and switch off all power.
is reduced.
®
®
is
from the voltage supply
®