Cylinder Technical Data - Mitsubishi Electric ecodan ECOSLIM150L-PP-MEUK Installation Manual

Table of Contents

Advertisement

Cylinder Technical Data

8
PRE-PLUMBED SLIMLINE CYLINDER UNIT
Nominal hot water volume (litres)
Water
Water Safety Devices
Dimensions (mm)
Weight empty/full (kg)
Cylinder Material
Electrical Data
Mechanical Zones
Optional simplified wireless room thermostat and wireless receiver
*1 MCB Sizes BS EN60898-2 & BS EN60947-2
Pre-Plumbed Slimline Cylinder Installation Manual
12
Flow Rate (l/min) W50 - W85
Pump
Connection Size (mm) Heating / DHW (mm)
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Water Circuit
Control Thermistor (°C)
Pressure Relief Valve (MPa (Bar))
Expansion Relief Valve (Cold)
DHW Tank
Control Thermistor
High Limit Stat (°C)
Temp and Pressure Relief Valve (°C)/ (MPa (Bar))
Width
Depth
Height
Tank
Cylinder Material
Heating Surface Area (m
Insulation
Insulation Type
Insulation Thickness (mm)
Standing Heat Loss (kWh/24hrs)
GWP of Insulation
ODP of Insulation
Control Board
Electrical Supply
optionally
Phase
powered by
outdoor unit
Fuse Rating - MCB Sizes (A)*1
Immersion
Electrical Supply
Heater
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1
*2 Optional 2 zone accessory available
ECOSLIM-
150L-PP-MEUK
150
14.3 - 25.8
1 x Grundfos UPS2 25-60
22
12
0.3 (3)
1 - 80
0.3 (3)
0.6 (6)
40-70
Mechanical 80
90 / 0.7 (7)
475
565
1880
65.5 / 215.5
Stainless Steel
)
2
Polyurethane (PU) Insulation with CO
50
1.31
Less than 5
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
13
16
DHW and 1 heating zone *2
PAR-WT50-E controller and PAR-WR51-E receiver
ECOSLIM-
180L-PP-MEUK
180
14.3 - 25.8
1 x Grundfos UPS2 25-60
22
19
0.3 (3)
1 - 80
0.3 (3)
0.6 (6)
40-70
Mechanical 80
90 / 0.7 (7)
475
565
1950
69.5 / 249.5
Stainless Steel
2
3
Blowing Agent
2
50
1.6
0
0
Less than 5
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
3
13
16
DHW and 1 heating zone *2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents