Mitsubishi Electric ecodan ECOSLIM150L-PP-MEUK Installation Manual page 52

Table of Contents

Advertisement

Main Controller
25
Setting the Main Controller
After the power and communication have been connected to the Ecodan
slimline cylinder the initial system settings can be entered via the main controller.
1. Check all breakers and other safety devices are correctly installed and turn on power to the system.
2. When the main controller switched on for the first time, the screen automatically goes to Initial settings
menu, Language setting screen and Date/Time setting screen in order.
3. Main controller will automatically start up. Wait approximately 6 minutes whilst the control menus load.
4. When the controller is ready a blank screen with a line running across the top will be displayed.
5. Press button E (Power) to turn on the system. Before turning on the system, perform initial settings as
instructed below.
Main Settings Menu
The main settings menu can be accessed by pressing the
MENU button. To reduce the risk of untrained end users
altering the settings accidentally there are two access
levels to the main settings; and the service section menu
is password protected.
User Level – Short press
If the MENU button is pressed once for a short time the
main settings will be displayed but without the edit
function. This will enable the user to view current settings
but not change the parameters.
Installer Level – Long press
If the MENU button is pressed down for 3 seconds the
main settings will be displayed with all functionality
available. The arrows shown at the bottom of the display
screen will invert colours and additional edit menus will be
displayed.
The following items can be viewed and/or edited
(dependent on access level).
• Domestic Hot Water (DHW)
• Heating/Cooling
• Schedule timer
• Holiday mode
• Initial settings
• Service (Password protected)
Use the F2 and F3 buttons to move between the icons.
The highlighted icon will appear as a larger version in the
centre of the screen. Press CONFIRM to select and edit
the highlighted mode.
Pre-Plumbed Slimline Cylinder Installation Manual
52
(continued)
and Mitsubishi Electric pre-plumbed
®

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents