Logic Output Function - Hitachi CONVENTION 14 Instruction Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Table of Contents

Advertisement

Master
Slave
Watchdog timer
C077 = xx.xx sec.
[NDc]
Alarm
C076 = 00 or 01

Logic Output Function

The Logic Output Function uses the inverter's built-in logic feature. You can select any
two of the other nine intelligent output options for internal inputs (use C141 and C142).
Then, use C143 to configure the logic function to apply the logical AND, OR, or XOR
(exclusive OR) operator as desired to the two inputs.
Intelligent outputs used
as internal inputs:
RUN, FA1, FA2,
OL, OD, AL, Dc,
FBV, NDc
RUN, FA1, FA2,
OL, OD, AL, Dc,
FBV, NDc
C141
Input A
Logic function
C142
AND, OR, XOR
Input B
Input Status
A
0
0
1
1
Time-out
[LOG]
[LOG] Output State
B
AND
OR
0
0
0
1
0
1
0
0
1
1
1
1
4 − 51
4 51
XOR
0
1
1
0