Alarm Code Output Function (Ac0 To Ac3) (C021 To C025, C062) - Hitachi L700 SERIES Instruction Manual

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Chapter 4 Explanation of Functions
4.2.65 Alarm code output function (AC0 to AC3)
The alarm code output function allows you to make the inverter
output a 3- or 4-bit code signal as the trip factor when it has
tripped.
Specifying "01" (3 bits) or "02" (4 bits) for the alarm code output (C062) forcibly assigns the alarm code
output function to intelligent output terminals [11] to [13] or [11] to [14], respectively.
The following table lists the alarm codes that can be output:
Intelligent output terminals
14
13
12
11
AC3
AC2
AC1
AC0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
Item
Alarm code output
When "4 bits" is selected
Factor code
Cause of tripping
Normal
Normal operation
E01 to E03,E04 Overcurrent protection
Overload protection
E05, E38
Low-speed overload
protection
Overvoltage/input
E07, E15
overvoltage protection
E09
Undervoltage protection
Instantaneous power failure
E16
protection
E30
IGBT error
Braking resistor overload
E06
protection
EEPROM, CPU, GA
E08, E11, E23
communication, or main
E25
circuit error
E10
CT error
External trip, USP error,
E12, E13, E35,
thermistor error, or braking
E36
error
E14
Ground-fault protection
Invalid instruction in easy
sequence
Nesting error in easy
E43, E44, E45
sequence
Easy sequence execution
command error
Temperature error due to low
E20, E21
cooling-fan speed
Temperature error
E24
Phase loss input protection
Easy sequence user trip 0-9,
E50 to E79
option 1,2 error 0-9
Function code
C062
C021 to C025: Terminal [11] to [15] functions
C062: Alarm code output
Factor code
E01 to E03, E04 Overcurrent protection
E07, E15
Data
00
01
02
4 - 68
Related code
When "3 bits" is selected
Cause of tripping
Normal
Normal
Overload protection
E05
Low-speed overload
protection
Overvoltage/input
overvoltage protection
E09
Undervoltage protection
Instantaneous power
E16
failure protection
E30
IGBT error
Other error
Description
No output of alarm code
Output of 3-bit code
Output of 4-bit code

Hide quick links: