Hitachi L700 SERIES Instruction Manual page 197

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Register
Function name
No.
1326h
Reduced voltage start selection
1327h
Function code display restriction
1328h
Initial-screen selection
Automatic user-parameter
1329h
setting function enable
132Ah
Torque limit selection
Torque limit (1) (forward-driving
132Bh
in 4-quadrant mode)
Torque limit (2)
132Ch
(reverse-regenerating in
4-quadrant mode)
Torque limit (3) (reverse-driving
132Dh
in 4-quadrant mode)
Torque limit (4)
132Eh
(forward-regenerating in
4-quadrant mode)
132Fh
Torque limit LADSTOP enable
1330h
Reverse Run protection enable
1331h to
(Reserved)
1333h
Controller deceleration and stop
1334h
on power loss
DC bus voltage trigger level
1335h
during power loss
Over-voltage threshold during
1336h
power loss
1337h
Deceleration time setting during
power loss (target voltage level)
1338h
Initial output frequency decrease
1339h
during power loss
Proportional gain setting for
133Ah
nonstop operation at momentary
power failure
Integral time setting for nonstop
133Bh
operation at momentary power
failure
133Ch to
(Reserved)
133Eh
Maximum-limit level of window
133Fh
comparators O
Minimum-limit level of window
1340h
comparators O
Hysteresis width of window
1341h
comparators O
Maximum-limit level of window
1342h
comparators OI
Minimum-limit level of window
1343h
comparators OI
Hysteresis width of window
1344h
comparators OI
Maximum-limit level of window
1345h
comparators OI
Minimum-limit level of window
1346h
comparators O/OI/O2
Hysteresis width of window
1347h
comparators O/OI/O2
1348h
(Reserved)
Operation level at O
1349h
disconnection
Operation level at OI
134Ah
disconnection
Operation level at O2
134Bh
disconnection
134Ch to
(reserved)
1350
Cumulative input power data
1351h
clearance
Cumulative input power display
1352h
gain setting
Chapter 4 Explanation of Functions
Function
R/W
Monitoring and setting items Data resolution
code
0 (minimum reduced voltage start time) to 255
b036
R/W
(maximum reduced voltage start time)
0 (full display), 1 (function-specific display), 2 (user
b037
R/W
setting), 3 (data comparison display), 4 (basicdisplay)
0 (screen displayed when the STR key was pressed
b038
R/W
last), 1 (d001), 2 (d002), 3 (d003), 4 (d007), 5 (F001)
b039
R/W 0 (disabling), 1 (enabling)
00 (quadrant-specific setting), 01 (switching by
b040
R/W
terminal), 02 (analog input), 03 (option 1),
04 (option 2)
b041
R/W 0 to 150 (no)
b042
R/W 0 to 150 (no)
b043
R/W 0 to 150 (no)
b044
R/W 0 to 150 (no)
b045
R/W 0 (disabling), 1 (enabling)
b046
R/W 0 (disabling), 1 (enabling)
-
-
Inaccessible
0 (disabling), 1 (enabling), 2, (nonstop operation at
momentary power failure (no restoration))
b050
R/W
3, (nonstop operation at momentary power failure
(restoration to be done))
b051
R/W 0 to 10000
b052
R/W 0 to 10000
b053 (high)
R/W
0 to 360000
b053 (low)
R/W
b054
R/W 0 to 1000
b055
R/W 0 to 255
b056
R/W 0 to 65535
-
-
Inaccessible
b060
R/W
0. to 100. (lower limit : b061 + b062 *2) (%)
b061
R/W
0. to 100. (lower limit : b060 - b062*2) (%)
b062
R/W
0. to 10. (lower limit : b061 - b062 / 2) (%)
b063
R/W
0. to 100. (lower limit : b064 + b066 *2) (%)
b064
R/W
0. to 100. (lower limit : b063 - b066 *2) (%)
b065
R/W
0. to 10. (lower limit : b063 - b064 / 2) (%)
b066
R/W
-100. to 100. (lower limit : b067 + b068 *2) (%)
b067
R/W
-100. to 100. (lower limit : b066 - b068 * 2) (%)
b068
R/W
0. to 10. (lower limit : b066 - b067 / 2) (%)
-
-
Inaccessible
b070
R/W
0. to 100. (%) or "no" (ignore)
b071
R/W
0. to 100. (%) or "no" (ignore)
b072
R/W
-100. to 100. (%) or "no" (ignore)
-
-
Inaccessible
b060
R/W Clearance by setting "1"
b060
R/W 1 to 1000
4 - 135
Register
No.
-
-
-
-
-
1 [%]
1 [%]
1 [%]
1 [%]
-
-
-
-
0.1 [V]
0.1 [V]
0.01
[sec.]
0.01 [Hz]
0.01
0.001
[sec]
-
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
-
1 [%]
1 [%]
1 [%]
-
-
1