Hitachi L700 SERIES Instruction Manual page 250

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Chapter 8 List of Data Settings
Code
Function name
Cumulative input power data
b078
clearance
Cumulative input power display gain
b079
setting
b082
Start frequency adjustment
b083
Carrier frequency setting
Initialization mode (parameters or trip
b084
history)
b086
Frequency scaling conversion factor
b087
STOP key enable
b088
Restart mode after FRS
b089
Automatic carrier frequency reduction
b090
Dynamic braking usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
Dynamic braking control
b096
Dynamic braking activation level
Thermistor for thermal protection
b098
control
b099
Thermal protection level setting
b100
Free-setting V/f frequency (1)
b101
Free-setting V/f voltage (1)
b102
Free-setting V/f frequency (2)
b103
Free-setting V/f voltage (2)
b104
Free-setting V/f frequency (3)
b105
Free-setting V/f voltage (3)
b106
Free-setting V/f frequency (4)
b107
Free-setting V/f voltage (4)
b108
Free-setting V/f frequency (5)
b109
Free-setting V/f voltage (5)
b110
Free-setting V/f frequency (6)
b111
Free-setting V/f voltage (6)
b112
Free-setting V/f frequency (7)
b113
Free-setting V/f voltage (7)
b130
Overvoltage suppression enable
b131
Overvoltage suppression level
Acceleration and deceleration rate at
b132
overvoltage suppression
Overvoltage suppression propotional
b133
gain
b134
Overvoltage suppression Integral time 0.000 to 9.999 / 10.00 to 65.53 (s)
(Note)<>indicate the setting range of 90 to 160kW
Monitored data or setting
Clearance by setting "01" and pressing the STR key
1. to 1000.
0.10 to 9.99 (Hz)
0.5 to 12.0 (kHz) (subject to derating)
<0.5 to 8.0 (kHz) (subject to derating)>
00 (clearing the trip history), 01 (initializing the data),
02 (clearing the trip history and initializing the data)
0.1 to 99.0
00 (enabling), 01 (disabling), 02 (disabling only the function to stop)
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (starting with active matching frequency)
00: invalid, 01: valid
0.0 to 100.0 (%)
00 (deceleration until stop), 01 (free-run stop)
00 (always operating the fan),
01 (operating the fan only during inverter operation [including 5 minutes
after power-on and power-off])
00 (disabling), 01 (enabling [disabling while the motor is topped]),
02 (enabling [enabling also while the motor is topped])
330 to 380, 660 to 760(V)
00 (disabling the thermistor), 01 (enabling the thermistor with PTC),
02 (enabling the thermistor with NTC)
0. to 9999. ( )
0. to "free-setting V/f frequency (2)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (3)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (4)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (5)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (6)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (7)" (Hz)
0.0 to 800.0 (V)
0. to 400. (Hz)
0.0 to 800.0 (V)
00 (disabling the restraint), 01 (controlled deceleration),
02 (enabling acceleration)
330 to 390 (V) (200 V class model), 660 to 780 (V)
(400 V class model)
0.10 to 30.00 (s)
0.00 to 2.55
8 - 8
Setting
Change
Default
during
during
operation
operation
(allowed
(allowed
_FF
or not)
or not)
00
1.
0.50
3.0
00
1.0
00
00
00
0.0
00
01
01
360/
720
00
3000.
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
00
380/
760
1.00
0.50
0.060
Page
4-3
4-43
4-44
4-78
4-2
4-9
4-53
4-45
4-46
4-9
4-46
4-75
4-16
4-42

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents