Message
695
Over Charge Power
Limit Warning
697
ADC Interrupt
Warning
701
Safety CRC Check
Error
702
Cell Over Voltage
Fault1
703
Cell Under Voltage
Fault1
705
Unit Over voltage
Fault1
706
Unit Under voltage
Fault1
707
Unit Voltage ADC
Mux Fault1
710
Discharge Over
Temperature Fault1
711
Discharge Under
Temperature Fault1
712
Charge Over
Temperature Fault1
713
Charge Under
Temperature Fault1
714
Terminal Over
Temperature Fault1
718
Discharge Over
Current Fault1
719
Charge Over Current
Fault1
721
Atmosphere
Discharge Over
Temperature Fault1
722
Atmosphere
Discharge Under
Temperature Fault1
723
Atmosphere Charge
Over Temperature
Fault1
42
Description
Charge Power level is higher than
the limit
Warning of the MCU AD interrupt
operation
Warning of the safety memory
range CRC data
Cell Voltage level of battery cell is
higher than the limit
Cell Voltage level of battery cell is
lower than the limit
Unit Voltage level of battery cell is
higher than the limit
Unit Voltage level of battery cell is
lower than the limit
Unit voltage AD conversion
multiplex fault
Discharge temperature level is
higher than the limit
Discharge temperature level is
lower than the limit
Charge temperature level is higher
than the limit
Charge temperature level is lower
than the limit
Power Terminal temperature level
is higher than the limit
Discharge current level is higher
than the limit
Charge current level is higher than
the limit
Discharge Atmosphere
temperature level is higher than
the limit
Discharge Atmosphere
temperature level is lower than the
limit
Charge Atmosphere temperature
level is higher than the limit
Solution
Automatically released after
warning condition is cleared
Automatically released after
warning condition is cleared
Automatically released after
warning condition is cleared
Automatically restart after
fault condition is cleared
Contact service center
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after
fault condition is cleared
Automatically restart after