Using The Air Purifier - Panasonic F-P04DXZ Operating Instruction

Table of Contents

Advertisement

Using the air purifier

Super alleru-buster indicator
Minus ion indicator
(green)
Air quality monitor
Predict pollutants and
stand by for air
purification
Patrol Mode
Pollutant sensor
characteristics
Odors from cigarette,
incense,
cooking and pets.
Cosmetics and alcohol.
Sprays.
8
(blue)
Operation indicators
Detects
The air quality monitor, Super alleru-buster, Minus ion,
Patrol Mode, and operation "Med" indicators come on.
The operation mode changes each time the button
is pressed:
"Patrol Mode" → "Allergen Mode" → "Lo" → "Med"
→ "Hi" → "Off".
After inserting the power plug for 2 minutes,
the Patrol Mode indicator will flash if the
Power / Speed button is pressed.
(During this time, the Patrol Mode function cannot
be used.)
If you select "Power/Speed", the unit shuts down and
all indicators go off.
(Operation indicators)
(Lit)
A Patrol Mode operation is performed.
A cycle of operation for 10 minutes and off for 50
minutes is repeated.
(Operation is performed with an air speed of "Mid".)
If pollutants are detected while the unit is off,
it will start at the fan speed corresponding to the
level of pollution detected.
(Operation indicators)
One of the
indicators will
be lit red, or off.
May detect
Humidity (water vapor).
Oil fumes.
Sudden temperature
changes such as when a
door is opened.
Press.
Off
(orange)
Does not detect
House dust
(dust, dead mites,
mite droppings, mold
spores, pollen).
Bacteria and viruses.

Advertisement

Table of Contents
loading

Table of Contents