SUN2000-(196KTL-H3, 200KTL-H3, 215KTL-H3)
Seires
User Manual
No.
Parameter
10
Threshold for
triggering
HVRT (V)
11
HVRT
gradient K1
12
HVRT
gradient K2
13
Grid voltage
protection
shield during
VRT
14
VRT exit
hysteresis
threshold
Issue 03 (2021-09-30)
Description
Specifies the threshold for triggering HVRT. The
threshold settings should meet the local grid
standard.
During HVRT, the solar inverter needs to
generate positive-sequence reactive power to
support the power grid. This parameter is used
to set the positive-sequence reactive power
generated by the solar inverter.
For example, if you set HVRT gradient K1 to 2,
the increment of positive-sequence reactive
current generated by the solar inverter is 20%
of the rated current when the AC voltage
increases by 10% during HVRT.
During HVRT, the solar inverter needs to
generate negative-sequence reactive power to
support the power grid. This parameter is used
to set the negative-sequence reactive power
generated by the solar inverter.
For example, if you set HVRT gradient K2 to 2,
the increment of negative-sequence reactive
current generated by the solar inverter is 20%
of the rated current when the AC voltage
increases by 10% during HVRT.
Specifies whether to shield the undervoltage
protection function during LVRT or HVRT.
Specifies the LVRT/HVRT recovery threshold.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
This parameter is
displayed when HVRT
is set to Enable.
This parameter is
displayed when LVRT
or HVRT is set to
Enable.
● This parameter is
displayed when
LVRT or HVRT is
set to Enable.
● LVRT recovery
threshold =
Threshold for
triggering LVRT +
VRT exit hysteresis
threshold
● HVRT recovery
threshold =
Threshold for
triggering HVRT -
VRT exit hysteresis
threshold