3 SPECIFICATIONS
Address
(Hexadecimal (Decimal))
CH1
CH2
2D
4D
H
H
(45)
(77)
2E
4E
H
H
(46)
(78)
2F
4F
H
H
(47)
(79)
30
50
H
H
(48)
(80)
31
51
H
H
(49)
(81)
32
52
H
H
(50)
(82)
33
53
H
H
(51)
(83)
34
54
H
H
(52)
(84)
35
55
H
H
(53)
(85)
36
56
H
H
(54)
(86)
37
57
H
H
(55)
(87)
38
58
H
H
(56)
(88)
39
59
H
H
(57)
(89)
3A
5A
H
H
(58)
(90)
3B
5B
H
H
(59)
(91)
3C
5C
H
H
(60)
(92)
3D
5D
H
H
(61)
(93)
3E
5E
H
H
(62)
(94)
3F
5F
H
H
(63)
(95)
A0
(160)
H
A1
(161)
H
A2
(162)
H
A3
(163)
H
A4
(164)
H
A5
(165)
H
A6
(166)
H
A7
(167)
H
A8
(168)
H
A9
(169)
H
AA
(170)
H
3 - 32
Downloaded from
ManualsNet.com
Settings
CH3
CH4
Sensor compensation value
6D
8D
H
H
setting
(109)
(141)
Adjustment sensitivity (dead band)
6E
8E
H
H
(110)
(142)
setting
6F
8F
H
H
Control output period setting
(111)
(143)
70
90
H
H
Primary delay digital filter setting
(112)
(144)
71
91
H
H
Control response parameter
(113)
(145)
72
92
H
H
AUTO/MAN mode switching
(114)
(146)
73
93
H
H
MAN output setting
(115)
(147)
74
94
H
H
Setting change rate limiter
(116)
(148)
75
95
H
H
AT bias
(117)
(149)
76
96
H
H
Forward/reverse action setting
(118)
(150)
Upper setting
77
97
H
H
(119)
(151)
limiter
Lower setting
78
98
H
H
(120)
(152)
limiter
79
99
H
H
Reserved
(121)
(153)
Heater disconnection alert setting
7A
9A
H
H
(122)
(154)
2
Loop disconnection detection
7B
9B
H
H
(123)
(155)
judgment time
Loop disconnection detection
7C
9C
H
H
(124)
(156)
dead band
7D
9D
H
H
Unused channel setting
(125)
(157)
2
7E
9E
E
PROM's PID constant read
H
H
(126)
(158)
command
Automatic backup setting after
7F
9F
H
H
auto tuning of PID constants
(127)
(159)
Reserved
Reserved
Reserved
Reserved
Alert dead band setting
Alert delay count
Heater disconnection/output off-
time current error detection delay
count
2
Temperature rise completion
range setting
Temperature rise completion soak
time setting
PID continuation flag
Heater disconnection
compensation function selection
2
1 : This setting may be changed only in the setting mode. Note that changing it in the operation mode will
result in a write data error (error code: 3). Also, Setting change command (YnB) must be turned on to
change the setting.
2: Available only for the Q64TCTTBW and Q64TCRTBW.
3: Indicates whether reading from and writing to a sequence program are enabled.
R : Reading enabled
W : Writing enabled
search engine
Range
-5000 to 5000
(-50.00 to 50.00%)
1 to 100(0.1 to 10.0%)
1 to 100(s)
0 to 100(s)
0: Slow, 1: Normal, 2: Fast
0: Auto (AUTO),
1: Manual (MAN)
-50 to 1050
(-5.0% to 105.0%)
0 to 1000
(0.0 to 100.0%/min)
±input range width
0: Forward action,
1: Reverse action
Q64TCTT(BW)
Within measurement range
Q64TCRT(BW)
Q64TCTT(BW)
Q64TCRT(BW)
0 to 100%
0 to 7200s
Input range width
0: Used, 1: Unused
0: Without command,
1: With command
0: OFF, 1: ON
0 to 100(0.0 to 10.0%)
0 to 255 (times)
3 to 255 (times)
1 to 10 (°C)
0 to 3600 (min)
0: Stop, 1: Continue
0: OFF, 1: ON
MELSEC-Q
Initial
Read/
Reference
value
write 3
section
Section
0
R/W
3.5.19
Section
5
R/W
3.5.20
Section
30
R/W
3.5.21
Section
0
R/W
3.5.22
Section
0
R/W
3.5.23
Section
0
R/W
3.5.24
Section
0
R/W
3.5.25
Section
0
R/W
3.5.26
Section
0
R/W
3.5.27
Section
1
R/W
3.5.28
1300
Section
R/W
6000
3.5.29
0
R/W
-2000
Section
0
R/W
3.5.30
Section
480
R/W
3.5.31
Section
0
R/W
3.5.32
Section
0
R/W
3.5.33
Section
0
R/W
3.5.34
Section
0
R/W
3.5.35
Section
5
R/W
3.5.36
Section
0
R/W
3.5.37
Section
3
R/W
3.5.38
Section
1
R/W
3.5.39
Section
0
R/W
3.5.40
Section
0
R/W
3.5.41
Section
0
R/W
3.5.42
3 - 32