Huawei SUN2000 Series User Manual page 72

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(12KTL-25KTL)-M5 Series
User Manual
Alarm
Alarm
ID
Name
2081
Optimize
r fault
2085
Built-in
PID
operation
abnormal
Issue 01 (2022-06-15)
Alarm
Possible Causes
Severity
combined or
exchanged.
● Cause ID = 8
The sunlight is
weak or changes
abnormally.
● Cause ID = 9
In partial
configuration
scenarios, the PV
string voltage
exceeds the
inverter input
voltage
specifications.
Warning
Cause ID = 1
The optimizer is
offline or faulty.
Minor
Cause ID = 1, 2
● The output
resistance of PV
arrays to ground
is low.
● The system
insulation
resistance is low.
Copyright © Huawei Digital Power Technologies Co., Ltd.
Troubleshooting
Go to the optimizer information screen
to view the fault details.
● Cause ID = 1
1. Turn off the AC output switch and
DC input switch, wait for a period
of time (for details about the wait
time, see the description on the
device safety warning label), and
then turn on the DC input switch
and AC output switch.
2. If the alarm persists, contact your
dealer or Huawei technical
support.
● Cause ID = 2
1. Check the impedance between the
PV array output and the ground. If
a short circuit occurs or the
insulation is insufficient, rectify the
fault.
2. If the alarm persists, contact your
dealer or Huawei technical
support.
8 Maintenance
66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents