Assembly
Please note:
Work areas must be
secured with protective
covers in accordance with
DIN EN 619. The user
must make openings with
a circumferential gap of
≤ 5 mm in the protective
covers for the stop gates,
switch brackets and
identifi cation system.
Dimensioned illustrations of
the openings, suitable for
the installation of
• stop gates
• switch brackets and
identifi cation systems
• positioning units
can be found in the
corresponding sections.
1.
Close off the open
section ends with end
plates and end caps.
2.
Put the spring elements
on the protective covers.
3.
Swing the protective
cover into the section.
The spring elements
snap into place in the
centering lugs of the
bearing pedestals.
Bosch Rexroth AG, MIT: HQ 5/H, HQ 5/XH, 3 842 558 544/2017-07
7.5.9

Installing protective covers for the section ends of an HQ 5

Do not walk on the protective covers!
Protective covers are only safety guards to prevent hand injuries.
Do not step on protective covers.
HQ5/XH
HQ5/H
HQ5/OC
T
Fig. 13:
Protective covers for the section ends of an HQ 5
CAUTION
SW
PZ2
M
=5 Nm
D
557 617-13