Fd01 (Inverter Status (Real Time)); Fd00 (Output Frequency (Real Time)); Fd03 (Output Current (Real Time)) - Toshiba DeviceNet Option DEV002Z-1 User Manual

Tosvert vf-as1/ps1 devicenet option function manual
Table of Contents

Advertisement

3.4.6.8. FD01 (Inverter status (real time))

bit
Function
0
FL
1
EMG
2
ALARM
3
(Reserved)
4
tHr2(VF2+tH2)
5
PI
6
ACC1/ACC2
7
DC braking
8
Jog
9
Fw/Reverse
10
Run/stop
11
Free run (ST)
12
Emergency stop
13
READY with ST/RUN
14
READY without ST/RUN
15**
Local/Remote
*
Ready for operation: Initialization completed, not a stop due to a failure, no alarm issued, not moff,
not a forced stop due to ll, not a forced stop due to a momentary power failure.
**
This function is reserved in VF-AS1.

3.4.6.9. FD00 (Output frequency (real time))

The current output frequency is read into 0.01Hz of units and by the hexadecimal number.
For example, when the output frequency is 80Hz, 0x1F40 (hexadecimal number) are read.
Since the minimum unit is 0.01%,
0x1F40 (Hex.) = 8000(Dec.) * 0.01 = 80 (Hz)
Also about the following parameters, these are the same as this.
- FD22 (Feedback value of PID (real time)) ................................. Unit: 0.01Hz
- FD16 (PG feedback or Estimated speed (real time))................. Unit: 0.01Hz
- FD29 (Input power (real time))................................................... Unit: 0.01kW
- FD30 (Output power (real time)) ................................................ Unit: 0.01kW

3.4.6.10. FD03 (Output current (real time))

The output current is read into 0.01% of units and by the hexadecimal number.
For example, when the output current of the rated current 4.8A inverter is 50% (2.4A), 0x1388
(hexadecimal number) is read.
Since the minimum unit is 0.01%,
0x1388 (Hex.) = 5000 (Dec.) * 0.01 = 50 (%)
Also about the following parameters, these are the same as this.
- FD05 (Output voltage(real time) ................................................... Unit: 0.01% (V)
- FD04 (Voltage at DC bus (real time) ............................................ Unit: 0.01%(V)
- FD18 (Torque ............................................................................... Unit: 0.01%
*
When the motor information connected to the inverter set to the parameter (f405 - f415), torque
monitor value "100%" is same as the rated torque of a motor in general.
0
No output
Under output
No fault
Under fault
No alarm
Under alarm
-
Motor 1
Motor 2
(THR1)
(THR2)
PI enable
PI off
Acc./Dec. 1
Acc./Dec. 2
(AD1)
(AD2)
OFF
DC braking
OFF
JOG RUN
Fwd. RUN
Rev. RUN
STOP
RUN
ST=ON
ST=OFF
No EMG. Stop Under EMG. Stop
Remote
Local
- 24 -
1
The rtry status and the trip
retention
status
regarded as tripped statuses.
-
THR1: thr
THR2: f173
AD1: acc, dec
AD2: f500, f501
ST = ON and RUN = ON in
addition to "ready for
(Nm)*
E6581281
Note
-
are
also
-
-
-
-
-
-
-
-
-
operation"*
-
-