5. Tighten the nuts to secure the monitor.
6. Mounting a chain to release the locking fitting.
The multiple installation fixture is so designed that the plasma display can be drawn forward for easy maintenance by
releasing the locking fittings. Attaching a chain to the locking fitting allows to easily release the locking mechanism
from the lowermost area.
For multiple installation, tags in three different colors (red, blue and yellow) are provided so that they can easily
differentiate each column or each unit from the others. It is, therefore, recommended that those tags are attached to
the chains.
7. Sliding prevention mechanism
A sliding prevention mechanism is provided to prevent any accident so that the plasma display will not inattentively
slide out when the multiple installation fixtures are mounted forward tilted or downward tilted.
• If you use those two nuts and two bolts that were removed when making preparations for installation as shown
below, it is possible to prevent sliding.
919 (Outer size of metal fixture)
Mounting standard metal fixtures (PDM-4001)
Place the nuts.
Insert a monitor securing bolt into a
potbellied hole on the slide frame,
and lower the bolt.
Tighten the nut.
Remove the bolts (both left
and right bolts)
Plasma display
Hook
Chain