Special installation (Wall embedding (vertically wall-embedding equipment))
3.4.6 Wall embedding (vertically wall-embedding equipment)
This display is designed to accommodate embedding in a wall. Since the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following conditions:
1 Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
2 Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3 Installation conditions and ambient operating temperatures:
(1) If the space behind the wall is open
C
Exhaust
100
m m
A
Working temperature requirements
A < 60
60 ≤ A < 150
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
4 2
A
A
Install the display with
the fan on top.
100
m m
A size
0~40°C
0~40°C
100 mm
100 mm
PC-9800 (56.4Hz)
VIDEO
Machintosh (66.7Hz)
VGA (60Hz)
0~40°C
0~40°C
A
PC-9800 (70.1Hz)
VGA (72.8Hz, 75Hz)
0~40°C
0~35°C