How To Enter; Sub Contrast Adjustment - Panasonic AG-513F Service Manual

Hide thumbs Also See for AG-513F:
Table of Contents

Advertisement

1. Enter EVR PG Shifter Adjustment mode, refer to
EVR PG SHIFTER ADJUSTMENT
2. Connect the channel-1 scope probe to TP3001 and the channel-2
scope probe to TP6205. Used TP6205 as a trigger.
3. Adjust value so that the trailing edge of the head switching pulse
is placed 6 H±1 H (0.38 ms±0.06 ms) before the start of the vertical
sync pulse.
4. Release EVR PG Shifter Adjustment Mode.
The adjusted value will be written to Memory IC (IC6004).

7.3.6. SUB CONTRAST ADJUSTMENT

Purpose:
To set the optimum sub contrast level.
Symptom of Misadjustment:
The picture is too dark or too light.
Test Point :
Pin 5 of P6001 (TV/VCR Main C.B.A.) or TP49 (CRT C.B.A.)
Adjustment :
SUB CONTRAST (EVR)
Specification :
3.0 V[p-p]±0.1 V[p-p]
INPUT :
Video Input Jack,
Crosshatch Pattern Signal 1 V[p-p]
(75
terminated)
MODE."
Fig. E5
59

"HOW TO ENTER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag-520f

Table of Contents