1. Enter EVR PG Shifter Adjustment mode, refer to
EVR PG SHIFTER ADJUSTMENT
2. Connect the channel-1 scope probe to TP3001 and the channel-2
scope probe to TP6205. Used TP6205 as a trigger.
3. Adjust value so that the trailing edge of the head switching pulse
is placed 6 H±1 H (0.38 ms±0.06 ms) before the start of the vertical
sync pulse.
4. Release EVR PG Shifter Adjustment Mode.
The adjusted value will be written to Memory IC (IC6004).
7.3.6. SUB CONTRAST ADJUSTMENT
Purpose:
To set the optimum sub contrast level.
Symptom of Misadjustment:
The picture is too dark or too light.
Test Point :
Pin 5 of P6001 (TV/VCR Main C.B.A.) or TP49 (CRT C.B.A.)
Adjustment :
SUB CONTRAST (EVR)
Specification :
3.0 V[p-p]±0.1 V[p-p]
INPUT :
Video Input Jack,
Crosshatch Pattern Signal 1 V[p-p]
(75
terminated)
MODE."
Fig. E5
59
"HOW TO ENTER