Download Print this page

Advertisement

Quick Links

Only five minutes!
How to use Epson DMM board
Rev1.00
The contents of this document are subject to change without notice.
© Seiko Epson Corporation. 2022

Advertisement

loading

Summary of Contents for Epson S5U1C17M03T

  • Page 1 Only five minutes! How to use Epson DMM board Rev1.00 The contents of this document are subject to change without notice. © Seiko Epson Corporation. 2022...
  • Page 2 Agenda Introduction DC voltage measurement Characteristic value Recording characteristic values Checking characteristic values Appendix Manual...
  • Page 3 1. Introduction The evaluation board "S5U1C17M03T" has a digital multimeter function loaded in the flash ROM, various measurements can be performed simply by turning on the power. S5U1C17M03T Evaluation board of MCU "S1C17M03" for digital multimeter...
  • Page 4: Dc Voltage Measurement

    2. DC voltage measurement ●Settings ●Measurement Set “0” to the mark at the Check Short the part of bottom center the display the red frame 1.500V Short the part of the red frame 1R00 MEAS Connect the PC and board Connect the probe to with a USB cable (TypeC) Connect the probe...
  • Page 5 3.1 Recording characteristic values Start "DmmEvalTool.exe" from the software package Check "COM" is displayed Push SW2 Example : DC voltage measurement Operate the tool on the next page Connect the probe to Connect the PC and board the measurement target with a USB cable (TypeC) to supply power...
  • Page 6 3.1 Recording characteristic values Click “START” to start reading the data Press SW2 at any time to finish reading the data. Example : DC voltage measurement When reading is completed, a "Logs" folder will be created and the measurement data "Output.csv"...
  • Page 7 3.2 Checking characteristic values First measurement Second measurement Data number of measurement Second data added Mode of A column is added measurement each time you record Open “Output.csv” and check Range of the characteristic value measurement Measurement data *The measurement data gets 16-bit digital values. (Excludes Capacity measurement and Frequency measurement) *Please close the csv file when recording the characteristic value.
  • Page 8 4. Appendix...
  • Page 9 You can switch to any measurement mode by setting the rotary switch. Check the correspondence between the set value, measurement mode and jumper setting from the table below. Except for default range, please refer to the “S5U1C17M03T Manual”. Measurement Mode...
  • Page 10: Cautions For Measurement

    Cautions for measurement If the evaluation board does not work as expected when performing “2. DC voltage measurement" and "3.1 Recording characteristic values", push SW5 (reset switch) and start over from the beginning of the procedure. No offset correction has been performed. Therefore, the actual input value and the value displayed on the LCD panel will differ.
  • Page 11 5. Reference manual Information Document MCU「S1C17M02/03」 S1C17M02/03 Technical manual Evaluation board S5U1C17M03T Manual 「S5U1C17M03T」 Software Application note...