Removing The Adf Reading Glass - Canon imageRUNNER 1750 Series Service Manual

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

4
Disassembly/Assembly > Original Exposure/Feed System > Removing the ADF Reading Glass

Removing the ADF Reading Glass

CAUTION:
• Place the removed ADF Reading Glass on a cloth, etc. to avoid damaging the
bottom sheet.
• When removing the ADF Reading Glass, take care not to touch the glass surface.
• If the surface becomes dirty, clean it with lint free paper.
1) Open the ADF Unit [1].
2) Remove the Glass Retainer Plate [2].
• 2 Screws [3]
[3]
x2
[2]
4
Disassembly/Assembly > Original Exposure/Feed System > Removing the ADF Reading Glass
3) Remove the ADF Reading Glass [1].
[1]
CAUTION:
• When removing the ADF Reading Glass, take care not to touch the glass surface.
• Attached soiling may cause white line/black line in the images.
• If soiling is attached, clean it with lint free paper moistened with alcohol.
• When installing the ADF Reading Glass, be sure that the sheet material [A] of the
ADF Reading Glass is on the left front side.
F-4-65
[1]
F-4-66
[A]
4-42
F-4-67
4-42