ABB Relion 615 Series Applications Manual

ABB Relion 615 Series Applications Manual

Motor protection and control
Hide thumbs Also See for Relion 615 Series:

Advertisement

Quick Links

®
Relion
615 series
Motor Protection and Control
REM615
Application Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB Relion 615 Series

  • Page 1 ® Relion 615 series Motor Protection and Control REM615 Application Manual...
  • Page 3 Document ID: 1YHT530017D05 Issued: 2014-05-14 Revision: B Product version: 4.1 © Copyright 2014 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
  • Page 5 ABB is not liable for any such damages and/or losses.
  • Page 6 (EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive.
  • Page 7: Table Of Contents

    Table of contents Table of contents Section 1 Introduction...............5 This manual..................5 Intended audience................5 Product documentation...............6 Product documentation set............6 Document revision history.............6 Related documentation..............7 Symbols and conventions..............7 Symbols..................7 Document conventions..............8 Functions, codes and symbols............8 Section 2 REM615 overview............11 Overview...................11 Product version history..............11 PCM600 and IED connectivity package version......12 Operation functionality..............12 Optional functions................12...
  • Page 8 Table of contents Default disturbance recorder settings........38 Functional diagrams..............38 Functional diagrams for protection.........38 Functional diagrams for disturbance recorder and supervision functions..............45 Functional diagrams for control and interlocking....47 Standard configuration B..............49 Applications.................49 Functions..................50 Default I/O connections............51 Default disturbance recorder settings........53 Functional diagrams..............53 Functional diagrams for protection.........54 Functional diagrams for disturbance recorder and supervision functions..............62...
  • Page 9 Table of contents Binary inputs................91 Optional light sensor inputs............93 Outputs.....................93 Outputs for tripping and controlling..........93 Outputs for signalling..............94 IRF....................95 Section 6 Glossary.................97 REM615 Application Manual...
  • Page 11: Section 1 Introduction

    Section 1 1YHT530017D05 B Introduction Section 1 Introduction This manual The application manual contains application descriptions and setting guidelines sorted per function. The manual can be used to find out when and for what purpose a typical protection function can be used. The manual can also be used when calculating settings.
  • Page 12: Product Documentation

    Product series- and product-specific manuals can be downloaded from the ABB Website http://www.abb.com/relion. 1.3.2 Document revision history Document revision/date Product version History A/2010-07-02 First release B/2014-05-14 Content updated to correspond to the product version Download the latest documents from the ABB Website http://www.abb.com/substationautomation. REM615 Application Manual...
  • Page 13: Related Documentation

    Section 1 1YHT530017D05 B Introduction 1.3.3 Related documentation Name of the document Document ID Modbus Communication Protocol Manual 1MRS756468 IEC 60870-5-103 Communication Protocol Manual 1MRS756710 IEC 61850 Engineering Guide 1MRS756475 Engineering Manual 1MRS757121 Installation Manual 1MRS756375 Operation Manual 1MRS756708 Technical Manual 1YHT530004D05 Symbols and conventions 1.4.1...
  • Page 14: Document Conventions

    Section 1 1YHT530017D05 B Introduction 1.4.2 Document conventions A particular convention may not be used in this manual. • Abbreviations and acronyms in this manual are spelled out in the glossary. The glossary also contains definitions of important terms. • Push-button navigation in the LHMI menu structure is presented by using the push-button icons.
  • Page 15 Section 1 1YHT530017D05 B Introduction Function IEC 61850 IEC 60617 IEC-ANSI Thermal overload protection for motors MPTTR1 3Ith>M Circuit breaker failure protection CCBRBRF1 3I>/Io>BF 51BF/51NBF Master trip TRPPTRC1 Master Trip (1) 94/86 (1) TRPPTRC2 Master Trip (2) 94/86 (2) Arc protection ARCSARC1 ARC (1) 50L/50NL (1)
  • Page 16 Section 1 1YHT530017D05 B Introduction Function IEC 61850 IEC 60617 IEC-ANSI Three-phase power and energy measurement PEMMXU1 P, E P, E RTD/mA measurement XRGGIO130 X130 (RTD) X130 (RTD) Frequency measurement FMMXU1 REM615 Application Manual...
  • Page 17: Section 2 Rem615 Overview

    REM615 is a member ® of ABB’s Relion product family and part of its 615 protection and control product series. The 615 series IEDs are characterized by their compactness and withdrawable- unit design.
  • Page 18: Pcm600 And Ied Connectivity Package Version

    • Label Printing • IED User Management • Application Configuration • Graphical Display Editor • Event Viewer Download connectivity packages from the ABB Website http://www.abb.com/substationautomation. Operation functionality 2.2.1 Optional functions • Arc protection • Modbus TCP/IP or RTU/ASCII • IEC 60870-5-103 •...
  • Page 19 Section 2 1YHT530017D05 B REM615 overview Table 2: Plug-in unit and case Main unit Slot ID Content options Plug-in Small (4 lines, 16 characters) unit Large (8 lines, 16 characters) X100 Auxiliary power/BO 48-250 V DC/100-240 V AC; or 24-60 V DC module 2 normally-open PO contacts 1 change-over SO contact...
  • Page 20: Local Hmi

    Section 2 1YHT530017D05 B REM615 overview Table 3: Number of physical connections in standard configurations Conf. Analog channels Binary channels RTD/mA 4 (12) 6 (10) 8 (14) 10 (13) 8 (16) 6 (10) 1) With optional RTD/mA module 2) With optional BIO module 3) One of the five channels reserved for future applications Local HMI The LHMI is used for setting, monitoring and controlling the IED.

This manual is also suitable for:

Rem615

Table of Contents