Network integration
6.3 Structure of the data block
Variable
Statistics
34
Data type
antenna
BYTE
polarization
BYTE
timestamp
Time_Of_Da
y
power
BYTE
filterData
BYTE
Available
Inventoried
WORD
Statistics
Gate
Entered
DINT
Read
DINT
NoRead
DINT
Timeout
DINT
TriggerWhile
DINT
Reading
NoReadAfter
DINT
Trigger
TooFast
ObjectLost
DINT
TagTop
DINT
TagBottom
DINT
TagUnclear
DINT
Offset
Offset
Comment
S7
TCP
86.0
90.0
Antenna (bit-coded)
87.0
81.0
Polarization
88.0
82.0
Time stamp
92.0
86.0
Power in [dBm]
93.0
87.0
--
94.0
88.0
--
96.0
90.0
--
96.0
90.0
Entered objects
100.0 94.0
Read objects
104.0 98.0
Unread objects
108.0 102.0 Timeout because the object
did not pass the light
barrier within 5 s.
112.0 106.0 Object entered but previous
object not finished.
116.0 110.0 NoRead after a new object has
initiated a trigger but the
previous object was not yet
finished.
120.0 114.0 An object was not processed
because the previous object
is still being processed and
the new object left the read
window during again during
this time.
124.0 118.0 Number of "Transponder top"
128.0 122.0 Number of "Transponder
bottom"
132.0 126.0 Number of "Position unknown"