3 Board
ID
LI2
LI3
LI4
M/S
PLL
Table 3-40 TMU ports
ID
RST
DBG
T2M
FCK
T13M
3-72
Color
Meaning
Green
E1 indicator
Green
E1 indicator
Green
E1 indicator
Green
Active/Standby
indicator
Green
Phase discrimination
indicator
The local alarm is the receiving tributary alarm of transmission line. The remote alarm is the sending
tributary alarm of transmission line.
If the TMU is standby, the LIn is corresponded to the alarm indicators of n +4-channel E1s. (n=1, 2, 3, 4)
Table 3-40
lists the description of the TMU ports.
Meaning
Reset button
Ethernet port
Clock output port
Clock output port
Clock output port
Huawei Technologies Proprietary
M900/M1800 BTS3X Series Base Transceiver Station
Indication
ON: The second E1 generates local alarm.
Flashing: The second E1 generates remote
alarm.
OFF: The second E1 is normal.
ON: The third E1 generates local alarm.
Flashing: The third E1 generates remote
alarm.
OFF: The third E1 is normal.
ON: The forth E1 generates local alarm.
Flashing: The forth E1 generates remote
alarm.
OFF: The forth E1 is normal.
ON for 500 ms and OFF for 500 ms.: TMU
is the active board.
ON for one second and OFF for one
second.: TMU is the standby board.
ON, OFF or flashing non-periodically:
TMU is faulty.
ON: Clock is running in free-run mode.
ON for 125 ms and OFF for 125 ms.: clock
is running in trapping mode.
ON for 500 ms and OFF for 500 ms.: Clock
is running in locking mode.
OFF: The phase discrimination of clock is
abnormal.
Port Type
Function
–
Reset button for the TMU
–
Debug network port
SMB
2 MHz output port
SMB
Frame clock output port
SMB
13 MHz output port
Hardware Description Manual
Issue 01 (2006-11-18)