Dsp for compact disk players

Advertisement

Bilingual Function
Code
$28
$29
$2A
* At reset or when a stereo command ($28) has been entered, Lch and Rch are output, respectively, to Lch and Rch.
* When the Lch set command ($29) is entered, the Lch data is output to both Lch and Rch.
* When the Rch set command ($2A) is entered, the Rch data is output to both Lch and Rch.
Deemphasis Pin 45: EMPH
Of the subcode Q control data, the pre-emphasis on/off bit is output from the EMPH pin. When this pin is high, the
deemphasis circuit within this IC is activated, and the D/A converter output are de-emphasized.
Digital Attenuator
It is possible to apply digital attenuation to the audio data by setting the RWC high and inputting from the COIN a two
byte command synchronized with the CQCK clock.
Code
$81
$82
$83
$84
$85
$86
$87
After reset, the attenuation level is set to "MUTE" (the attenuation coefficient is 00H, where MUTE = –∞), and thus it is
necessary to directly set the attenuation coefficient EEH using the direct set (ATT DATA SET) command in order to
produce a sound. The attenuation level can be set to a range from 00H to EEH (239 different levels) by the
microcontroller commands.
This two byte command is different from the two byte commands used in track counting in that RWC only needs to be
set once, and it is not necessary to reset the two byte command either. (See the two byte command RWC1 set on page
13.)
Command
After inputting the target attenuation level in terms of 00H to EEH, then if the attenuate step-up/step-down commands are
transmitted, the system steps closer to the target with the corresponding step size of 4, 8, or 16, synchronized with the
rising edge of LRSY. However, when the ATT DATA SET command has been used, then the target value is set directly.
When new data is entered during the transition, then the target value is approached from whatever value is in effect at
that time. Caution is required when using the step-up/step-down commands at this time.
LC78626KE
COMMAND
STO CONT
Lch CONT
Rch CONT
COMMAND
ATT
DATA
SET
ATT
4STEP
UP
ATT
4STEP
DOWN
ATT
8STEP
UP
ATT
8STEP
DOWN
ATT
16STEP
UP
ATT
16STEP
DOWN
Attenuation data 00H to EEH
RES = low
RES = low
DATA 00H Set