3.
Loosen the terminal screw and insert the cable into the terminal.
Screw size
Tightening torque
M2
0.22 Nm to 0.25 Nm
NOTE
• Undertightening may cause cable disconnection or malfunction. Overtightening can cause a short circuit or malfunction due
to damage to the screw or unit.
• When wiring the RS-485 terminals on the inverter with the plug-in options installed, be careful not to let RS-485 cables touch
the option circuit boards and the inverter circuit board. This is to prevent a malfunction due to electromagnetic noises.
• When one position detector is shared between FR-A8AP and CNC (computerized numerical controller), its output signal
should be connected as shown below. In this case, the wiring length between FR-A8AP and CNC should be as short as
possible, within 5 m.
CAUTION
• Do not use empty terminals as junction terminals because they are used internally used by the option. Doing so may damage the plug-in
option.
• After wiring, do not leave wire offcuts in the inverter. Doing so may cause a fault, failure or malfunction.
Cable gauge
2
0.3 mm
to 0.75 mm
Inverter
(FR-A8AP)
Maximum 5 m
(two parallel cables)
Screwdriver
Small flathead screwdriver
(tip thickness: 0.4 mm / tip width: 2.5 mm)
Position detector
Encoder
CNC
INSTALLATION AND WIRING