30/128 Product information
Relative oil humidity
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19
Fig. 4: Configuration of the evaluation of the serial signal of the particle sensor
The average particle content is output via P-0-1292. The individual values of the particle
content are output via P-0-1424 (S), P-0-1425 (M), P-0-1426 (L) and P-0-1427 (XL).
Sensor 6.510 at port 5 of the IO link gateway is used to measure the relative oil
humidity.
If the sensor is not present, the value -999 is output. If the sensor measures an
invalid value, -999 is output as well and warning B325 is issued.
Relative oil humidity is output in P-0-1272. The measured temperature value of the
sensor is not used.
Table 10: Parameters for relative oil humidity
Function
Parameter
P-0-1272
P-0-1389[13]
P-0-1389[14]
P-0-1389[15]
Description
Unit
Actual value
%
Warning
%
Error
%
Debouncing time
ms
Bytes
Decimal
Default
points
4
1
-
4
3
85
4
3
95
4
3
0