32/128 Product information
Oil filter (pressure filter)
and return flow filter
Leakage flow
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19

5.3.3 Monitoring systems

The following monitoring functions are provided:
The monitoring of the oil filter and of the optional return flow filter are active if the
drive controller is enabled and the minimum oil temperature (P-0-1389[29]) for the
debouncing time (P-0-1389[24]) has been reached.
This status is established with a cycle time of 200 ms.
For the oil filter, the pressure differential between the filter pressure (P-0-1273) and
the system pressure (S-0-0813) is monitored. The monitoring is based on a cycle
time of 1 ms.
Table 13: Oil filter monitoring
Message
Threshold value
[bar]
Warning
P-0-1389[30]
Error
P-0-1389[31]
In addition, the actual pressure value of the return flow filter (P-0-1283) is
monitored. The monitoring is based on a cycle time of 1 ms.
Activation/deactivation of the monitoring for oil and return flow filter:
Oil filter:
P-0-1380 Bit 20
Return flow filter: P-0-1380 Bit 21
FALSE = not activated; TRUE = activated
Table 14: Return flow filter monitoring
Message
Threshold value
[bar]
Warning
P-0-1389[33]
Error
P-0-1389[34]
The monitoring of the leakage flow is active if a measured value via an I/O link sensor
is present. The monitoring is based on a cycle time of 1 ms.
Table 15: Leakage flow monitoring
Message
Threshold value
[l/min]
Warning
P-0-1389[39]
Error
P-0-1389[40]
Debouncing
Diagnostic
time [ms]
number
B306
P-0-1389[32]
D306
Debouncing
Diagnostic
time [ms]
number
B327
P-0-1389[35]
D327
Debouncing
Diagnostic
time [ms]
number
B318
P-0-1389[38]
D318
Bit in status word
(P-0-1412/P-0-1413)
6
Bit in status word
(P-0-1412/P-0-1413)
-
Bit in status word
(P-0-1412/P-0-1413)
11