10-link digital output module dq 8x24vdc/2a 8xm12 (25 pages)
Summary of Contents for Siemens SIMATIC ET 200AL
Page 1
Equipment Manual SIMATIC ET 200AL Digital output module DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Edition 08/2021 support.industry.siemens.com...
Page 2
Digital output module DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Preface ET 200AL Documentation Guide SIMATIC Product overview Wiring ET 200AL Digital output module Parameters/address space DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Interrupts/diagnostic alarms Equipment Manual Technical specifications PROFIenergy Dimension drawing 08/2021 A5E36683723-AB...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
This arrangement enables you to access the specific content you require. Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200AL distributed I/O system. The STEP 7 online help supports you in the configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, wiring diagrams, characteristics and technical specifications.
Page 7
You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en). "mySupport" - Documentation With "mySupport", your personal workspace, you make the best out of your Industry Online Support.
Page 8
You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA SIEMENS PRONETA (PROFINET network analysis) allows you to analyze the plant network during commissioning. PRONETA features two core functions: • The topology overview automatically scans the PROFINET and all connected components.
Page 9
ET 200AL Documentation Guide SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
Product overview Properties Article number 6ES7142-5AF00-0BA0 View of the module Figure 2-1 View of the DQ 8x24VDC/2A 8xM12 digital output module Digital output module DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Equipment Manual, 08/2021, A5E36683723-AB...
Page 11
• M8 sealing cap • M12 sealing cap See also You can find more information on accessories in the Accessories/spare parts section of the ET 200AL distributed I/O system (https://support.industry.siemens.com/cs/us/en/view/89254965) system manual. Digital output module DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Equipment Manual, 08/2021, A5E36683723-AB...
Product overview 2.2 Operator controls and display elements Operator controls and display elements The figure below shows the operator controls and display elements of the DQ 8x24VDC/2A 8xM12 digital output module. ① DIAG: LED display for the diagnostic status ② X10 to X17: Sockets for the output signal ③...
Wiring Terminal and block diagram The example in the figure below shows the pin assignment of signal outputs. ① Output to 1L+ X10 to X17 Channels 0 to 7 ② Output to 2L+ Infeed of the ET-Connection ③ DQ circuit 1L+ Loop-through of the ET-Connection ④...
Wiring 3.2 Pin assignment Pin assignment Note Color coding The sockets for ET-Connection and the power supply of the modules are color-coded. These colors correspond to the colors of the offered cables. Pin assignment of the sockets for digital outputs The tables below show the pin assignments of the 8 sockets for connection of the digital outputs.
Page 15
Wiring 3.2 Pin assignment Pin assignment of the sockets for ET-Connection The table below shows the pin assignments of the 2 sockets for the connection of ET-Connection. Table 3- 2 Pin assignment for ET-Connection Assignment Assignment of the Front view of the sockets wire color of the X30 socket X31 socket...
Page 16
Wiring 3.2 Pin assignment Pin assignment of the socket for loop-through of the supply voltage The table below shows the pin assignment of the socket for loop-through of the supply voltage. Table 3- 4 Pin assignment of the supply voltage socket Assignment Assignment of the Front view of the...
Parameters/address space Parameters The table below shows the parameters for the DQ 8x24VDC/2A 8xM12 digital output module. Table 4- 1 Parameters Parameters Value range Default Scope Diagnostics: Missing load voltage 2L+ • Disable Module Disable • Enable Diagnostics: Short-circuit to ground Disable Module •...
Parameters/address space 4.2 Explanation of the parameters Explanation of the parameters Diagnostics: Missing load voltage 2L+ Enabling of the diagnostics for missing or insufficient load voltage 2L+. Diagnostics: Short-circuit to ground Enabling of the diagnostics for short-circuit of the output to ground. Reaction to CPU/master STOP With this parameter, you set the reaction of the digital outputs of the module after a CPU/master STOP:...
Parameters/address space 4.3 Address space Address space The figure below shows the assignment of the address space for the digital output module DQ 8x24VDC/2A 8xM12 with value status (Quality Information, QI). The address space for the value status is allocated by the module, if the value status is configured using the PROFINET interface module.
Interrupts/diagnostic alarms Status and error displays LED displays The figure below shows the LED displays (status and error displays) of the digital output module DQ 8x24VDC/2A 8xM12. ① Diagnostic status (DIAG) (red/green) ② Channel status (0 to 7) (green) ③ Load voltage 2L+ (PWR) (green) Figure 5-1...
Page 21
Interrupts/diagnostic alarms 5.1 Status and error displays Meaning of the LEDs The following tables set out the meaning of the status and error displays. Remedial measures for diagnostic alarms can be found in the section Diagnostics alarms (Page 21). DIAG LED Table 5- 1 Error display of the DIAG LED DIAG LED...
Interrupts/diagnostic alarms 5.2 Interrupts Interrupts The digital output module DQ 8x24VDC/2A 8xM12 supports diagnostics interrupts. Diagnostic interrupt The digital output module generates a diagnostic interrupt at the following events: • Short-circuit of outputs to ground • Load voltage 2L+ missing or too low Diagnostics alarms For each diagnostic event, a diagnostics alarm is issued and the DIAG LED flashes red on the digital output module.
Technical specifications of the DQ 8x24VDC/2A 8xM12 digital output module The following table shows the technical specifications as of the issue date. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7142-5AF00-0BA0/td?dl=en). Article number 6ES7142-5AF00-0BA0...
Page 24
Technical specifications 6.1 Technical specifications Article number 6ES7142-5AF00-0BA0 Power loss Power loss, typ. Digital outputs Number of digital outputs 4; 2 load groups for 4 outputs each • in groups of Short-circuit protection Yes; per channel, electronic 2.8 A • Response threshold, typ.
Page 25
Technical specifications 6.1 Technical specifications Article number 6ES7142-5AF00-0BA0 Potential separation channels • between the channels, in groups of • between the channels and backplane bus No; 4 channels are non-isolated and 4 channels • between the channels and the power sup- are isolated from supply voltage 1L+ ply of the electronics Isolation...
Additional information You can find additional information on working with PROFIenergy in the "PROFIenergy" section of the manual IM 157-1 PN interface module (https://support.industry.siemens.com/cs/ww/en/view/89254863) and the "Saving energy with PROFIenergy" section of function manual PROFINET with STEP 7 V13 (https://support.industry.siemens.com/cs/ww/en/view/49948856).
PROFIenergy 7.2 Behavior of the digital output module Behavior of the digital output module Display The channel status LEDs are directly affected by the signal level at the socket. Response to error detection All channels that are in pause mode on "PE_MODE_PROCEED" report their diagnostic status as in productive mode.
Dimension drawing The figure below shows the dimension drawing of the DQ 8x24VDC/2A 8xM12 digital output module in front and side views. Figure A-1 Dimension drawing Digital output module DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BA0) Equipment Manual, 08/2021, A5E36683723-AB...