Advertisement

Quick Links

Remote Controller Manual
MODEL
RC-AGS1EA0E
Remote Controller manual
Page
1~28
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
<0024394D>
-1-

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RC-AGS1EA0E

  • Page 1 Remote Controller Manual MODEL RC-AGS1EA0E Remote Controller manual Page 1~28 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. <0024394D>...
  • Page 2: Names And Functions Of Remote Controller

    Names and Functions of Remote Controller This controls the operation function and timer setting of the room air conditioner. The range of control is about 7 meters. lf indoor lighting is controlled electronically, the range of control may be shorter. Signal Transmission Invalid Operation Sign Off Mode Sign...
  • Page 3: How To Set Clock

    How to Install the Batteries in the Remote Controller Push and pull to the Remove the cover as shown in the figure and take out the old batteries. dirction of arrow Batteries Install the new batteries. The direction of the batteries should match the marks in the case. CAUTION Cover 1.
  • Page 4: Various Functions

    Various Functions Auto Restart Control If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction. (As the operation is not stopped by remote controller.) If you intend not to continue the operation when the power is resumed, switch off the power supply. When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction.
  • Page 5: Heat Mode

    Heat Mode Use the device for heating when the outdoor temperature is under 24°C. When it is too warm (over 24°C), the heating function may not work in order to protect the device. In order to keep reliability of the device, please use this device above –15°C of the outdoor temperature.
  • Page 6: Dry Mode

    Dry Mode Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. Press the Mode Selector Button so that the display indicates (Dry). The fan speed is set at Auto. Press (Fan Speed) button to select Silent, Low or Auto fan speed.
  • Page 7: Cool Mode

    Cool Mode Use the device for cooling when the outdoor temperature is -10 to 46°C. If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor unit. Press the Mode Selector Button so that the display indicates (Cool).
  • Page 8: Powerful Operation

    Powerful Operation • By pressing (Powerful) button during Auto, Heat, Dry, Cool, or Fan operation, the air conditioner Powerful performs at maximum power. • During Powerful operation, cooler or warmer air will be blown out from indoor unit for Cooling or Heating operation respectively.
  • Page 9 Indoor FrostWash operation The dust and dirt adhering to indoor heat exchanger which is the cause of the smell. They are washed away by freezing and thawing of the heat exchanger. FrostWash function can work when the outdoor temperature is 1℃ to 43℃ and Indoor humidity is 30% to 70%. The process of indoor FrostWash is pressed Operation is started...
  • Page 10 FrostWash (Auto Mode) and Fan Reverse (Auto Mode) How to enable FrostWash (Auto) and Fan Reverse (Auto) FrostWash (Auto) and Fan Reverse (Auto) enable. If FrostWash (Auto) and Fan Reverse (Auto) How to disable FrostWash (Auto) and Fan Reverse (Auto) FrostWash (Auto) and Fan Reverse (Auto) disable.
  • Page 11 Outdoor FrostWash operation FrostWash 5℃ 25℃ 5℃ 25℃. Outdoor FrostWash operation will operate automatically (accumulated operation or standby time reaches 60 days). During operation of outdoor frostwash, a bit of condensation on the base pan surface of the outdoor unit is normal.
  • Page 12 Fan Reverse (Auto Mode) By rotating the fan of the outdoor in the reverse direction when the unit is stopped, dust on the outdoor heat exchanger is blown away. Fan Reverse auto start conditions Unit normal operation Waiting for the outdoor Waiting for the Fan (Outdoor fan normal Fan Reverse...
  • Page 13 Mold Guard Operation After the cooling operation is stopped, the fan of the indoor unit is dried by heating or fan mode to  suppress the generation of mold inside the indoor unit. - Mold Guard Operation period is about 100 minutes. - It can't remove mold or sterilize.
  • Page 14 Smart Eco operation • The sensor detects the presence of people in the room. When nobody is detected, the unit automatically starts energy saving operation by shifting the set temperature in two steps. • Smart Eco button is scrolling button , First Press of button , it will start Eco operation , on second Press of button it will start Eco with Auto-Off operation and on Third press of button , it will cancel Eco and Eco with Auto-Off function.
  • Page 15 Smart Eco Logic When the presence of people is not detected for 20 minutes, the set temperature is automatically shifted for energy saving. If nobody is in the room for 60 minutes, the set temperature is shifted further. Cooling operation [diagram representation Heating operation [diagram representation for illustrative purpose only] for illustrative purpose only]...
  • Page 16 Power Safe (Max Current Switching ) • This function limit the maximum current during the operation of Air conditioner so it will help to avoid breaker trips if maximum current reaches to breaker limit. it limits the electrical current during operation.
  • Page 17 SleepSense Operation • With motion sensor, the room air conditioner detects movements, its location and temperature around people to control set temperature and control fan speed to provide comfortable and energy saving operation as well as to achieve comfortable sleep environment. To Start SleepSense operation ●...
  • Page 18 SleepSense Operation LOGIC ( SleepSense) ● At First the Unit will operate at Cooling or Heating mode for 20 minutes at setting condition. ● With the motion sensor, the room air conditioner can monitor human movement. If no human movement is detected, then the temperature will increase ( in case of cooling operation ) or decrease 1°C ( in case of Heating) automatically and unit continues running for 1 hour.
  • Page 19: Silent Mode

    Silent Mode (Silent) button during Auto, Heat, Dry, Cool or Fan operation, the fan speed changes (Silent) (On/Off) (Silent) (Fan Speed) Silent Silent Powerful Silent Silent Silent Silent (Silent) By Pressing Mode button or LeaveHome button or My Mode button , Silent operation is cancelled. -19-...
  • Page 20 User can use the device simply as an air circulator. Press the M selector button so that the display indicates Press the button. Fan Speed (High) (Super High) START Press the button. Fan operation starts with a beep. STOP Press the button again to stop operation. Adjusting the Airflow Direction(upward and downward) Adjust the airflow upward and downward.
  • Page 21 Adjust the Airflow Direction(leftward and rightward) Adjusting the airflow leftward and rightward parallelly. Adjustment of airflow in Left and Right direction. Press the Left/Right button . The deflector(s) will start to swing Left and Right side parallely. is display on LCD screen. Press the Left/Right button again.
  • Page 22: Timer Reservation

    Timer Reservation 1. Off Timer Setting The device can be set to turn off at a preset time. Press ( Timer OFF) Button to select OFF timer. Symbol start blinking and 12:00 or Previously set time will be display on LCD screen. Set up desire Turn off time by pressing Temperature Up /Down button After setting , point the remote controller towards the indoor unit...
  • Page 23 Initialization of the Built-in airCloud Home Module You can reset the internal settings (restore the factory settings) by remote controller.  How to restore factory setting Please make this setting with the remote control in off mode. Press button (Mode) and button (On Timer) 3 seconds ...
  • Page 24 My Mode(Programming) Use this mode for personalized comfortable settings. The My Mode can be set by using the remote controller. Up to 3 programs can be set. Programming of My Mode Default Setting of My Mode My Mode Mode Temperature Fan Speed ON Timer / Silent OFF Timer...
  • Page 25 My Mode(Programming) Programming of My Mode On Timer Setting Press ( Timer ON) Button to select ON timer. Symbol start blinknig on LCD screen. ON Timer time will be display on clock time segment on LCD. Press button to set desire ON timer. Press button .
  • Page 26 My Mode(Start or Stop of My Mode Operation) Start of My Mode Operation Start of My Mode Operation Press (My Mode) button at room air conditioner operation. Room air conditioner starts with My Mode 1 registered to remote controller. Press (My Mode) button again in order to change to the operation of My mode 2, My mode 3.
  • Page 27 Operation Mode Lock The remote controller can be set to fix the Heat Mode (including Fan Mode), Cool Mode and Dry Mode (including Fan Mode) operations. Method to lock Heat Mode (including Fan Mode) operation. Press (Mode) and buttons simultaneously for about 3 seconds when the remote controller is OFF.
  • Page 28 How to Reset Filter Sign on the indoor unit Filter Sign on the indoor unit will show with “ ” lamp by blinking with 1 second on and 4 seconds off. Because cleaning of Air filter has not been done for a long time. Clean the Air filter.

Table of Contents