Huawei SUN2000-250KTL Series User Manual page 78

Hide thumbs Also See for SUN2000-250KTL Series:
Table of Contents

Advertisement

SUN2000-(250KTL, 280KTL, 300KTL, 330KTL) Series
User Manual
Check Item
System running
status
Electrical
connection
Grounding
reliability
Vegetation
around the
SUN2000
Figure 8-2 Removing the baffle of the air intake vent
After the cleaning is complete, reinstall the baffle plate. Tighten the M4 screws
with a torque of 1.2 N·m.
Issue 02 (2022-12-20)
Criteria
● The SUN2000 is not damaged
● The SUN2000 does not generate
● All SUN2000 parameters are
● Cables are securely connected.
● Cables are intact. In particular,
● The sealing plugs of unused DC
● The unused COM and USB ports
Ground cables are securely
connected.
● Perform inspection and weeding
● Clean the site promptly after
NO TICE
Copyright © Huawei Technologies Co., Ltd.
or deformed.
abnormal sounds during
operation.
correctly set during operation.
the parts in contact with
metallic surfaces are not
damaged.
input terminals are secured.
are locked by waterproof caps.
as required.
weeding.
8 System Maintenance
Maintenance
Interval
Once every 6 months
6 months after the
first commissioning
and once every 6 to
12 months after that
6 months after the
first commissioning
and once every 6 to
12 months after that
Based on the local
wilting season