Download Print this page

NEC VT695 Control Commands page 14

Control commands
Hide thumbs Also See for VT695:

Advertisement

Supplement:
The projector does not accept the other command during power on processing.
016. POWER OFF
**********************************************************************
Function:
This command switches off the main power of the projector.
Command:
02H 01H 00H 00H 00H 03H
Response: At the time of a success
22H 01H 01H xxH 00H CKS
(*1) (*2)
(*3)
Response: At the time of a failure
A2H 01H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
Supplement:
The projector doesn't accept the other command during power off processing. (It contains a cooling period.)
018. INPUT SW CHANGE
**********************************************************************
Function:
This command switches the input terminal or the entry list.
Command:
02H 03H 00H 00H 02H DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA01
Switching object
00H : Entry List
01H : Input terminal
DATA02
Switching number
---------------------------------------------------------
When the switching object is the "Signal list", the signal list number is specified. (0...99)
---------------------------------------------------------
When the switching object is the "Input connector", the input connector number is specified.
(*4)
(*3)
(*3)

Advertisement