Download Print this page

NEC VT695 Control Commands page 23

Control commands
Hide thumbs Also See for VT695:

Advertisement

Response: At the time of a failure
A3H 94H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
037-4. LAMP INFORMATION REQUEST 3
**********************************************************************
Function:
This command acquires the information on the projector lamp in Eco mode.
Command:
03H 96H 00H 00H 02H DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA01
Target
00H : Lamp1
01H : Lamp2
DATA02
item
01H : Lamp usage time (second)
04H : lamp remaining amount until lamp warning message
(100% to -10%)
08H : Remaining time until lamp warning message starts
to appear (in terms of specified values)
09H : Remaining time until lamp warning message starts
to appear (in terms of Normal mode values)
0AH : Remaining time until lamp warning message starts
to appear (in terms of Eco mode values)
10H : Remaining time until inhibition of lamp usage
(in terms of specified values)
11H : Remaining time until inhibition of lamp usage
(in terms of Normal mode values)
12H : Remaining time until inhibition of lamp usage
(in terms of Eco mode values)
Response: At the time of a success
23H 96H 01H xxH 06H DATA01 .. DATA06 CKS
(*1) (*2)
Data Portion Contents
-------------------------------------------------------------------
DATA01
same values as DATA01 of the command
DATA02
same values as DATA02 of the command
DATA03 .. 06 Acquired information
Response: At the time of a failure
A3H 96H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
Supplement:
* In case of acquiring lamp's use of hours
03H 96H 00H 00H 02H 00H 01H 9CH
(*4)
(*3)
(*3)
(*3)
(*4)
(*3)

Advertisement

loading