Data Portion Contents
-------------------------------------------------------------------
DATA01
00H fixed
DATA02 ... 03
Projector type
See DATA13...14
DATA04 ... 12
Model name (NULL termination character string)
DATA13 ... 14
Projector type
DATA02 DATA03 DATA13 DATA14
00H
02H
00H
02H
00H
02H
00H
01H
01H
03H
01H
03H
02H
05H
02H
05H
02H
02H
02H
02H
02H
02H
03H
08H
DATA15 ... 16
Reserved
Response: At the time of a failure
A0H BFH 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
305-3. PROJECTOR INFORMATION REQUEST
**********************************************************************
Function:
This command acquires basic operation states of projector.
Command:
00H BFH 00H 00H 01H 02H C2H
Response: At the time of a success
20H BFH 01H xxH 10H DATA01 ... DATA16 CKS
(*1) (*2)
Data Portion Contents
-------------------------------------------------------------------
DATA01
02H fixed
DATA02
Projector Processing Status
00H : Idle
04H : Power On
05H : Cooling
06H : Idle(Error Standby)
Other : Not Support
Other than above : (nondisclosure)
Internal use of code during a state transition period
00H
05H
00H
06H
01H
06H
00H
06H
00H
06H
00H
07H
00H
05H
00H
05H
00H
05H
00H
06H
00H
07H
00H
07H
(*4)
(*3)
(*3)
LT245/LT265
LT380
LT280
NP1000/NP2000/NP1150/NP2150/NP3150
VT80 Series
VT90 Series
HT410
HT510
LT180
LT25/LT30/LT35
NP40/NP50/NP60
NP4000/NP4001

Advertisement