Auto Function (Standard); Manually Adjusting The Sensitivity; Pinpointing Leaks - Beko METPOINT CID Quick Start Manual

Hide thumbs Also See for METPOINT CID:
Table of Contents

Advertisement

METPOINT
®
CID

9.5.2 Auto function (standard)

The auto function (automatic sensitivity level selection) is activated by default. In other words, the
measured ultrasound level is used to automatically set the optimal measuring range.
Example: Level = 71 dB -> stage: 20 ... 80 dB

9.5.3 Manually adjusting the sensitivity

You can also switch between individual sensitivity levels manually. To do this, use the "sensitivity
adjustment button."
Users can use this option to reduce noise and find leaks as quickly and easily as possible. 
To do so, they must keep increasing or reducing the sensitivity and using the adjusted sensitivity
to scan the target area for leaks. When the sensitivity level is reduced, the device will focus on a
smaller area, but will also lose range.

9.5.4 Pinpointing leaks

The specific approach recommended for pinpointing leaks depends on the specific ambient 
conditions in question.
Option 1 ... from which direction can you hear a leak?
When using this method, you should point in all directions until you find the loudest point. After 
this, you should move in the direction of the loudest point in order to be able to accurately
pinpoint the leak.
This option works well when there is little noise.