2 Engineering of the STEP 7 program
Symbol
error
stateNumber
status
Reading QR Codes with SIMATIC MV320 via ET200SP CM PtP
Article ID: 109474684,
V2.0,
Data type
BOOL
UINT
WORD
10/2021
Description
Is set if the block "Port_Config",
"Receive_P2P", or "Receive_Reset" was
terminated with an error.
The pending error for the user to fix can be
acknowledged with a positive edge at "init".
Status from the internal state machine when the
error occurs:
2: "Port_Config" error
3: "Receive_Reset" error
4: "Receive_P2P" error
Error information
Note:
You can find the meaning of the codes in the
online help of the commands "Port_Config",
"Receive_Reset", and "Receive_P2P".