External Cache Problems

The amount of cache displayed by the power-on
diagnostics program is incorrect.
You may have installed the external cache chips incorrectly.
They may be the wrong type, or they may not be inserted all
the way. Also, make sure the tag chip you've installed is 20ns
for all microprocessors except the 486DX/50 or Pentium
OverDrive processor. For these processors, the tag chip must be
15ns.
Also, you may not have changed the SETUP program or the
jumpers to recognize the new cache. Make sure you have set
the External cache option to Enabled and set both the
System shadow and the Video shadow optionsto
Enabled.
See Chapter 4 for instructions on changing the jumper settings
or for information on installing external cache. See Chapter 2
for instructions on using the SETUP program.

Internal Battery Problems

The screen displays an error message prompting you to run
SETUP when you start your system, or your system displays
an incorrect time and date.
If your system has not been used for an extended period of
time, your internal NiCad backup battery may be discharged.
First, run SETUP to enter the correct time and date. (You may
also need to reenter your computer's configuration
information.) See Chapter 2 for instructions. Then, keep your
system running for several hours to recharge the NiCad battery.
Troubleshooting 6-15