Download Print this page
Huawei SUN2000-100KTL-M2 Quick Manual

Huawei SUN2000-100KTL-M2 Quick Manual

Hide thumbs Also See for SUN2000-100KTL-M2:

Advertisement

Quick Links

SUN2000-(100KTL, 110KTL, 115KTL)-M2
Quick Guide
Issue: 02
Part Number: 31500HMG
Date: 2023-03-13
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

loading

Summary of Contents for Huawei SUN2000-100KTL-M2

  • Page 1 SUN2000-(100KTL, 110KTL, 115KTL)-M2 Quick Guide Issue: 02 Part Number: 31500HMG Date: 2023-03-13 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 (2) DC switch 1 (DC SWITCH 1) controlled by DC SWITCH 1) (3) Reset button 1 (RESET 1) (4) DC input terminal group 2 (PV9–PV14, controlled by DC SWITCH 2) Copyright © Huawei Technologies Co., Ltd. 2023. All rights reserved.
  • Page 3: Installation Requirements

    (5) DC switch 2 (DC SWITCH 2) (6) Reset button 2 (RESET 2) (7) DC input terminal group 3 (PV15–PV20, (8) DC switch 3 (DC SWITCH 3) controlled by DC SWITCH 3) (10) Ventilation valve (9) Reset button 3 (RESET 3) (11) USB port (12) Communications port (COM) (13) Hole for the AC output power cable...
  • Page 4 Dimensions Installing a Solar Inverter • This quick guide describes how to install a solar inverter on a support. For details about wall- mounted installation, see the user manual. Position for binding the • The M12x40 bolt assemblies are delivered with the security Torx wrench solar inverter.
  • Page 5: Connecting Cables

    1. Install the mounting bracket. It is recommended that anti-rust measures be taken on the positions for drilling holes. 2. Install the solar inverter onto the mounting bracket. 3. Tighten security Torx screws. Connecting Cables • Do not connect loads between the inverter and the AC switch that directly connects to the inverter.
  • Page 6 • Connect cables in accordance with the local installation laws and regulations. • To prevent poor cable connection due to overstress, leave enough slack before connecting the cables to the appropriate ports. Preparations • S and S are the conductor cross-sectional areas of AC power cables and PE cables respectively. •...
  • Page 7 Conductor Cross- No. Cable Type Outer Diameter Sectional Area DC input power PV cable that meets the 1100 V 4–6 mm 5.5–9 mm cable standard • One or two communicatio ns cables: 4– RS485 Outdoor shielded twisted pair that 11 mm communications 0.25–1 mm meets the local standard...
  • Page 8 Opening the Maintenance Compartment Door • Do not open the panel of the solar inverter. • Before opening the maintenance compartment door, turn off the downstream AC output switch and three DC switches at the bottom. • Do not open the maintenance compartment door on rainy or snowy days. If you need to, take protective measures to prevent rain or snow from entering the maintenance compartment.
  • Page 9 3. Remove the accessories and set them aside. 4. Select a crimping module according to the type of the AC output power cable. Multi-core Cable Single-core Cable...
  • Page 10 Removing the Rubber Rings from the Crimping Module Use scissors to cut off the joints of the rubber rings to remove them. All rubber rings are removed in the same way. Remove the corresponding rubber rings strictly according to the cable diameter range, and ensure that the crimping module is not damaged.
  • Page 11 Installing the AC Output Power Cable • The cable outer diameter can be measured using the ruler sticker in the maintenance compartment. • Ensure that the AC output power cable is secured. Failure to do so may cause the solar inverter to malfunction or damage to its terminal block by issues such as overheating.
  • Page 12 Single-core Cable Connection Method...
  • Page 13 Cable Connections Four-core cable Four-core cable Five-core cable Three-core cable (including N) (including PE) Single-core cable Single-core cable (including N) (excluding N) Closing the Maintenance Compartment Door...
  • Page 14 Installing DC Input Power Cables Selecting DC Input Terminals Before connecting the PV string to the inverter, check that the PV string output is well insulated to the ground. Use an insulation resistance tester to add a voltage of 1500 V between the PV– cable and the ground, and then check that the resistance value is greater than or equal to 1 MΩ.
  • Page 15 Installing DC Input Power Cables 1. Use the positive and negative Amphenol Helios H4 metal contacts and DC connectors supplied with the solar inverter. Using incompatible positive and negative metal contacts and DC connectors may result in serious consequences. The caused device damage is not covered under any warranty.
  • Page 16 Connector connection: Installing RS485 Communications Cables Pin Definitions of Communications Ports • The solar inverter supports RS485 communication and MBUS communication. If the MBUS communication mode is used, you do not need to connect the communications cable to the RS485-1 port. •...
  • Page 17 Port Definition Definition Description RS485A IN, RS485 RS485A OUT, RS485 Used for cascading differential signal+ differential signal+ solar inverters or RS485-1 connecting to devices RS485B IN, RS485 RS485B OUT, RS485 such as the differential signal– differential signal– SmartLogger. Protection PE, shielding ground PE, shielding ground –...
  • Page 18: Verifying The Installation

    Connecting RS485 Communications Cables (4–8 mm Two-hole or Three-hole Rubber Plug) One or two Three communications communications cables cables One communications cable Verifying the Installation Acceptance Criteria The solar inverter is installed correctly and securely. The DC switches and downstream AC switch are set to OFF. All cables are connected correctly and securely.
  • Page 19 • Before turning on the AC switch between the solar inverter and the power grid, check that the AC voltage is within the specified range using a multimeter set to the AC position. Do not turn the DC switch to the unloaded position •...
  • Page 20 Scenario in Which Solar Inverters Are Connected to the FusionSolar Smart PV Management System 1. Open the FusionSolar app, log in to intl.fusionsolar.huawei.com using an installer account, and choose Me > Device commissioning. Then, scan the QR code on the WLAN module or the bar code on the Bluetooth module, or manually connect to the device via the WLAN hotspot, Bluetooth, or USB port to access the device commissioning screen.
  • Page 22 Huawei Technologies Co., Ltd. Huawei Industrial Base, Bantian, Longgang Shenzhen 518129 People's Republic of China https://e.huawei.com...

This manual is also suitable for:

Sun2000-110ktl-m2Sun2000-115ktl-m2