1. Select the SD card in the PC under "Choose disk"
2. Select the previously created backup copy under "Choose file".
3. Select „<<Restore<<"
After the message "Writing has completed ..." the SD card can be plugged into the
corresponding RD55UP12-V module and then the controller can be switched on.
4 OPC UA server function
This chapter explains how to connect the IoT Gateway to controllers and make their global
variables available as OPC UA tags for clients.
4.1 iQ-R CPU
4.1.1 Configure SLMP Connection
In order for the Mitsubishi controller to be accessible via OPC UA, the SLMP Connection
Module must be inserted using the GX Works configuration software.
Important: In order for data to be written externally to the OPC UA tags, "Enable all (SLMP)"
must be selected!
_________________________________________________________________________