Opc Ua Server Function; Iq-R Cpu; Configure Slmp Connection - Mitsubishi Electric RD55UP12-V Manual

Iot gateway, ibhsoftec opc ua server function
Table of Contents

Advertisement

1. Select the SD card in the PC under "Choose disk"
2. Select the previously created backup copy under "Choose file".
3. Select „<<Restore<<"
After the message "Writing has completed ..." the SD card can be plugged into the
corresponding RD55UP12-V module and then the controller can be switched on.

4 OPC UA server function

This chapter explains how to connect the IoT Gateway to controllers and make their global
variables available as OPC UA tags for clients.

4.1 iQ-R CPU

4.1.1 Configure SLMP Connection

In order for the Mitsubishi controller to be accessible via OPC UA, the SLMP Connection
Module must be inserted using the GX Works configuration software.
Important: In order for data to be written externally to the OPC UA tags, "Enable all (SLMP)"
must be selected!
_________________________________________________________________________
Document: Quickstart_IoTGateway_EN
Rev: 001G
Date: 01/02/2022
Mitsubishi Electric Europe B.V.
14

Advertisement

Table of Contents
loading

Table of Contents