Toshiba LF664 Instruction Manual page 40

Electromagnetic flowmeter detector
Hide thumbs Also See for LF664:
Table of Contents

Advertisement

 
Principal materials:
Case・・・・carbon steel
Lining・・・Natural rubber
Electrodes・・・AISI316L (std.), Titanium (opt.), Hastelloy C equivalent (opt.)
Grounding rings・・・None (std.), AISI304(opt), AISI316(opt), Titanium (opt.),
Measuring tube・・・AISI304
Coating: Polyurethane coating (std.), pearl-gray colored
Note: If the optional IP68 and NEMA 6P continuous submersible type structure is specified,
the coating is tar epoxy resin coating.
Cable connection port: 1/2-14NPT male screw for both signal cable and exciting cable.
Cable length: Allowable cable length between the converter and the detector varies with the electrical
conductivity of fluid. See Figure 9.1.
11.81 (300)
7.87 (200)
3.94 (100)
1.97 (50)
1.18 (30)
0.79 (20)
0.39 (10)
Allowable cable length (m)
〔m〕
0.20 (5)
Electrical conductivity (µS/cm)
0.12 (3)
Hastelloy C equivalent (opt.)
300
200
100
50
30
20
10
5
3
3
5
3
5
導電率〔μS/cm〕
Electrical conductivity (μS/cm)
Figure 9.1 Electrical Conductivity vs. Cable Length
 
10
20 30
50
100 200
10
20
30
50
100
39
6F8A0943
200