Hitachi PC-ARFG2-M Installation & Maintenance Manual page 19

Advanced color wired remote controller
Hide thumbs Also See for PC-ARFG2-M:
Table of Contents

Advertisement

No.
Item
Optional Function
126
q8
Not used
127
q9
Not used
128
qA
Not used
129
qb
Operation mode with Setback
Temp. differential for the Setback
130
qC
operation
131
qd
Minimum stop time of Setback
132
qE
Setback Mode
Operation state after Setback
133
qF
operation ends
134
r1
Dual Setpoint
Differential temp. setting for
135
r2
Cooling-Heating changeover
Setback Temperature
136
r3
Compensation
137
r4
Enable/Disable Auto-FrostWash 2
138
r5
Not used
139
r6
FrostWash Manual Setting
140
r7
FrostWash Automatic Setting
141
r8
Enable/Disable Auto-FrostWash
Remote control prohibition during
142
r9
Setback operation
A16381TMEL
Individual
Setting
Setting
Condition
00
00
-
01
01
00
00
-
01
01
00
00
-
01
01
00
Unavailable
01
COOL only
×
02
HEAT only
03
COOL & HEAT
00
2.0°C(3°F)
01
3.0°C(5°F)
×
4.0°C(7°F)
02
03
5.0°C(9°F)
04
1.0°C (2°F)
10 min.
00
20 min.
01
30 min.
02
03
40 min.
04
50 min.
05
60 min.
×
06
70 min.
07
80 min.
08
90 min.
09
100 min.
10
110 min.
11
120 min.
00
Always
01
Input
×
02
Schedule
03
Manual
00
Stop
×
01
Run
02
State before Setback Operation
00
Unavailable
×
01
Available
00
1.0°C (2°F)(Default)
01
1.5°C (3°F)
02
2.0°C (3°F)
×
03
2.5°C (4°F)
04
3.0°C (5°F)
05
0.5°C (1°F)
05
0.5°C (1°F)
10
1.0°C (2°F)
15
1.5°C (3°F)
20
2.0°C (3°F)
25
2.5°C (4°F)
×
30
3.0°C (5°F)
35
3.5°C (6°F)
40
4.0°C (7°F)
45
4.5°C (8°F)
50
5.0°C (9°F)
55
5.5°C (10°F)
00
Available
-
01
Unavailable
00
00
-
01
01
00
Allow
×
01
Prohibit
00
Allow
×
01
Prohibit
00
Disable
×
01
Enable
00
Run/Stop allowed
×
01
Run & Stop not allowed (not advised for safety reasons)
02
Only stop allowed
6. Function Selection