Cabling Controllers To Drive Shelves; Cabling Storage On A Two-Controller Switchless Cluster With No External Storage; Cabling Storage On An Ha Pair With External Drive Shelves - Lenovo ThinkSystem DM3000x Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

Step
Cable the management ports to the management network
3
switches.
DO NOT the plug power cords in at this point.
Step 2.
To cable your storage, see

Cabling controllers to drive shelves

You must cable the controllers to your drive shelves or to the onboard SAS ports if you only have onboard
drives and no external drive shelves.
Cabling storage on a two-controller switchless cluster with no external
storage
You must cable the SAS ports together in a two-controller switchless cluster so that both controllers can
access the partner's onboard storage.
Step 1.
Cable the SAS ports on your two-controller switchless cluster, without external storage, using the
following steps:
AC
Step
Perform on each controller
Cable the SAS ports.
1
Step 2.
To complete setting up your system, see

Cabling storage on an HA pair with external drive shelves

You must cable the shelf-to-shelf connections, and then cable both controllers to the drive shelves.
ThinkSystem DM3000x and DM5000x Hardware Installation and Maintenance Guide
22
Perform on each controller
"Cabling controllers to drive shelves" on page
AC
"Completing system setup and configuration" on page
Ports used
• e0M
Not applicable.
22.
Ports used
• Controller 1 0a to
Controller 2 0b.
• Controller 1 0b to
Controller 2 0a.
23.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem dm5000x7y417y427y577d7w7d7u ... Show all

Table of Contents