Connection cable
Connection cable consists of 2 pieces of flat cable assembly
(X42-3510-10), to extend its cable length double for connection
between two PCBs.
For repair and adjustment, use this connection cable to connect
a Control PCB and a TX-RX PCB by inserting the connection
cable to connectors on these PCBs.
Note:
If Control PCB and TX-RX PCB are disassembled from the
main chassis, there may possibly cause short-circuit, electrical
shock or the high-frequency signal interference.
To verify the transmit state, be sure to keep Control PCB and
TX-RX PCB assembled in a chassis.
Besides, transmission without a heat sink attached may
possibly cause the device to be damaged.
Be sure to verify the transmit performance with LOW/EL
transmit power transmitted in a short amount of time.
4.4
Adjustment Mode
Outline
(1) Set the transceiver to adjustment mode and change each
setting data item.
(2) This mode is used when the PCBs are replaced at a
service center or at the time of making transceiver
readjustments.
Note:
All adjustment data is stored in the flash memory (TX-RX
1/7: CONTROL IC705).
Operation procedures in adjustment mode
(1) Turn ON the transceiver.
(2) Short-circuit two lands (SET and GND) on the component
side of the TX-RX unit (1/7) to set the transceiver to
adjustment mode.
When the transceiver is set to adjustment mode, the
adjustment items for the battery will be displayed.
Short
(No.RA044<Rev.001>)1-29