Item
Condition
B-Band
17)Frequency: 469.95MHz
SSG:-110dBm(0.707μV)
Mode:FM(3kHz)
AF VR:0.63V/8 ohm
2.IF Filter
1)Frequency: 145.953MHz
Calibration
SSG:-53dBm(501μV)
Mode:FM OFF
1)Frequency: 145.947MHz
SSG:-53dBm(501μV)
Mode:FM OFF
3.Squelch and
1)Frequency: 145.950MHz
S-meter
SQL Level1
A-Band
SSG:-124dBm (0.14μV)
S-1
SSG:-120dBm(0.22μV)
S-FULL
SSG: -105dBm(1.26μV)
Mode: FM(3kHz)
2)Frequency: 439.95MHz
SQL Level1
SSG:-125dBm(0.126μV)
S-1
SSG:-120dBm(0.22μV)
S-FULL
SSG: -105dBm(1.26μV)
Mode: FM(3kHz)
B-Band
3)Frequency: 145.950MHz
SQL Level1
SSG:-125dBm(0.126μV)
S-1
SSG:-120dBm(0.22μV)
S-FULL
SSG: -105dBm(1.26μV)
Mode: FM(3kHz)
4)Frequency: 224.50MHz
SQL Level1
SSG:-122dBm(0.178μV)
S-1
SSG:-117dBm(0.32μV)
S-FULL
SSG: -102dBm(1.77μV)
Mode: FM(3kHz)
5)Frequency: 439.95MHz
SQL Level1
SSG:-125dBm(0.126μV)
S-1
SSG:-120dBm(0.22μV)
S-FULL
SSG: -105dBm(1.26μV)
Mode: FM(3kHz)
1-40 (No.RA044<Rev.001>)
Measurement
Test-
Unit
Terminal
equipment
SSG
ANT
Oscilloscope
SP
Audio analyzer
SSG
ANT
SP
SSG
ANT
SP
SSG
ANT
SSG
ANT
SSG
ANT
SSG
ANT
SSG
ANT
Adjustment
Unit
Parts
Method
[Auto]
Automatic
Max RSSI value
adjustment
[Auto]
Automatic
adjustment
[Auto]
Automatic
adjustment
[] or
Write
[Write]
[] or
Write
[Write]
[] or
Write
[Write]
[] or
Write
[Write]
[] or
Write
[Write]
Specifications
/Remarks

Hide quick links:

Advertisement

loading