Note1: This is the value measured while removed from the chassis. Use a short transmission burst. In the worst case scenario, some parts will be damaged. During this test,
some parts will reach high temperature.
Note2: For the 1kHz MOD to become 8mVrms, set the MIC input terminal to AG.
Note3: Set the transmission output to Low.
1
Note4: Connect a 50Ohm terminal load or power meter to the ANT terminal.
Note5: RF levels for each point, other than for the ANT terminal, are measured at 1000pF with a spectrum analyzer through a capacitor.