Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 235

Table of Contents

Advertisement

Parameter
Parameter
Register
41000 to
0 to 999
41999
C2(902)
41902
42092
C3(902)
43902
125(903)
41903
42093
C4(903)
43903
C5(904)
41904
42094
C6(904)
43904
126(905)
41905
42095
C7(905)
43905
C22(922)
41922
C23(922)
42112
C24(923)
41923
C25(923)
42113
Faults history
Register
40501
Fault history 1
40502
Fault history 2
40503
Fault history 3
40504
Fault history 4
40505
Fault history 5
40506
Fault history 6
40507
Fault history 7
40508
Fault history 8
Data
Definition
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
* Refer to page 279 for details of fault definition.
Parameter Name
Refer to the parameter list (page
58) for the parameter names.
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting bias
(Analog value)
Terminal 2 frequency setting bias
(Terminal analog value)
Terminal 2 frequency setting gain
frequency
Terminal 2 frequency setting gain
(Analog value)
Terminal 2 frequency setting gain
(Terminal analog value)
Terminal 4 frequency setting bias
frequency
Terminal 4 frequency setting bias
(Analog value)
Terminal 4 frequency setting bias
(Terminal analog value)
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting gain
(Analog value)
Terminal 4 frequency setting gain
(Terminal analog value)
Frequency setting voltage bias
frequency (built-in
potentiometer)
Frequency setting voltage bias
(built-in potentiometer)
Frequency setting voltage gain
frequency (built-in
potentiometer)
Frequency setting voltage gain
(built-in potentiometer)
Definition
Read/write
Read/write
Fault code list
Data
Definition
H31
E.THM
H40
E.FIN
H52
E.ILF
H60
E.OLT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
HA1
E.OP1
Communication operation and setting
Read/
Write
The parameter number + 41000 is the register
Read/write
number.
Read/write
Read/write The analog value (%) set to C3 (902) is read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
Read/write The analog value (%) set to C4 (903) is read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
Read/write The analog value (%) set to C6 (904) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C7 (905) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C23 (922) is read.
Read/write
Read/write The analog value (%) set to C25(923) is read.
Being 2 bytes in length, the data is stored as
Read
"H00
".
Read
Refer to the lowest 1 byte for the error code.
Read
Read
Performing write using the register 40501 batch-
Read
clears the faults history.
Read
Set any value as data.
Read
Data
Definition
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC5
E.IOH
HC7
E.AIE
HC8
E.USB
HD8
E.MB4
Remarks
Remarks
Data
Definition
HD9
E.MB5
HDA
E.MB6
HDB
E.MB7
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13
233
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents