Pilot Control Shut-Off Lever

Pilot control shut-off lever (1) functions to prevent the
machine from being mistakenly operated when the operator
accidentally touches the control lever or pedals when getting
on or off the machine.
d
WARNING:
 Always pull pilot control shut-off lever (1) into the
full LOCK position. Unless pilot control shut-off lever
(1) is fully moved to the LOCK position, the control
lever is not locked, possibly creating a hazardous
situation.
 When leaving the machine, always stop the engine.
Then, pull pilot control shut-off lever (1) up to the
LOCK position.
 Always pull pilot control shut-off lever (1) up to the
LOCK position before transporting the machine and
leaving the machine.
 Confirm that pilot control shut-off lever (1) is in the
LOCK position before starting the engine. The engine
will not start in any position other than the LOCK
position.