Toshiba TOSVERT VF-S15 Function Manual page 26

Hide thumbs Also See for TOSVERT VF-S15:
Table of Contents

Advertisement

4.2.2.
Relation parameters for VF-AS3
Communi
Title
cation No.
C001
Scanner input 1 address
c001
C002
Scanner input 2 address
c002
C003
Scanner input 3 address
c003
C004
Scanner input 4 address
c004
C005
Scanner input 5 address
c005
C006
Scanner input 6 address
c006
C021
Scanner output 1 address
c021
C022
Scanner output 2 address
c022
C023
Scanner output 3 address
c023
C024
Scanner output 4 address
c024
C025
Scanner output 5 address
c025
C026
Scanner output 6 address
c026
(*1): The unit depends on f519 setting
Function
0: -
1: fa06 (Communication command 1)
2: fa23 (Communication command 2)
3: fa07 (Frequency command, 0.01Hz)
4: fa33 (Torque command 0.01%)
5: fa50 (Terminal output data)
6: fa51 (Analog output(FM) data from comm.)
7: fa52 (Analog output(AM) data from comm.)
8: f601 (Stall prevention level, %)
9: f441 (Power running torque limit 1
10: f443 (Regenerative braking torque
11: f460 (Speed loop proportional gain)
12: f461 (Speed loop stabilization coefficient)
13: acc (Acceleration time 1, 0.1s) (*1)
14: dec (Deceleration time 1, 0.1s) (*1)
15: ul
16: vb
17: vlv
0-17 (Same as c001)
0-17 (Same as c001)
0-17 (Same as c001)
0-17 (Same as c001)
0-17 (Same as c001)
0: -
1: fd01 (Status information 1)
2: fd00 (Output frequency, 0.01Hz)
3: fd03 (Output current, 0.01%)
4: fd05 (Output voltage, 0.01%)
5: fc91 (Inverter alarm)
6: fd22 (PID feedback value, 0.01Hz)
7: fd06 (Input terminal status)
8: fd07 (Output terminal status)
9: fe35 (RR input, 0.01%)
10: fe36 (RX input, 0.01%)
11: fe37 (II input, 0.01%)
12: fd04 (Input voltage (DC detection), 0.01%)
13: fd16 (
14: fd18 (Torque, 0.01%)
15:fe60 (My monitor)
16:fe61 (My monitor)
17:fe62 (My monitor)
18:fe63 (My monitor)
19: f880 (Free notes)
20: fd29 (Input power, 0.01kW)
21: fd30 (Output power, 0.01kW)
22: fe14 (Cumulative operation time, 1hour)
23: fe40 (FM terminal output monitor, 0.01%)
24: fe41 (AM terminal output monitor, 0.01%)
25: fd20 (Torque current, 0.01%)
26: fd23 (Motor overload factor, 0.01%)
27: fd24 (Drive overload factor, 0.01%)
28: fd25 (PBR overload factor, %)
29: fd26 (Motor load factor, %)
30: fd27 (Drive load factor, %)
31: fe56 (Pulse train input, pps)
32: fe70 (Drive rated current, 0.1A)
33: fe76 (Input Watt-hour, 0.1kWh  10
34: fe77 (Output Watt-hour, 0.1kWh  10
35: fd83 (IGBT temperature, degree C)
0-35 (Same as c021)
0-35 (Same as c021)
0-35 (Same as c021)
0-35 (Same as c021)
0-35 (Same as c021)
- 23 -
Description
level,0.01%)
limit 1 level, 0.01%)
(Upper limit, 0.01Hz)
(Torque boost value 1, 0.01%)
(Base frequency voltage 1, 0.1V)
Estimated speed (real-time value), 0.01Hz)
E6582051
)