7.2. Example2. Read the inverter parameter

When access to inverter parameter, set "0x03E8" (1000) to the PNU, and set the communication No. of
inverter parameter to IND.
7.2.1.
Request Format (Read the value of
Field
Request Header (Byte 1)
Request Header (Byte 2)
Request Header (Byte 3)
Request Header (Byte 4)
Parameter Address (Byte 1)
Parameter Address (Byte 2)
Parameter Address (Byte 3)
Parameter Address (Byte 4)
Parameter Address (Byte 5)
Parameter Address (Byte 6)
* Refer to section 0.
7.2.2.
Response format
Field
Request Header (Byte 1)
Request Header (Byte 2)
Request Header (Byte 3)
Request Header (Byte 4)
Parameter Value (Byte 1)
Parameter Value (Byte 2)
Parameter Value (Byte 3)
Parameter Value (Byte 4)
* Refer to section 0.
** Value 0x31EC is "12780" in decimal, and minimum setting unit of
Therefore, this value means "127.80 (%)".
(Input voltage))
fd04
Description
Request Reference
Request ID (0x01: Request) *
Axis
Number of Parameters
Attribute
Number of Elements
Parameter number (PNU), High byte
Parameter number (PNU), Low byte
Sub index (IND), High byte
Sub index (IND), Low byte
Description
Request Reference (mirrored)
Response ID *
Axis (mirrored)
Number of Parameters
Format *
Number of Values
Values, High byte
Values, High byte
- 57 -
E6582051
Value
0x01
0x01
0x01
0x01
0x10
0x01
0x03
0xE8
0xFD
0x04
Value
0x01
0x01
0x01
0x01
0x06
0x01
0x31 **
0xEC **
(Input voltage) is 0.01%.
fd04