12 Inspection and maintenance
Pos: 61 /Beko Technische Dokumentation/Sicherheit/Gefahr Druckluft @ 0\mod_1184148143854_2901.docx @ 5778 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which
are not secured.
Pos: 62 /Beko Technische Dokumentation/Sicherheit/Maßnahmen Druckluft BM @ 0\mod_1184148284291_2901.docx @ 5814 @ @ 1
Measures:
•
Do not exceed the maximum operating pressure (see type plate).
•
Only carry out service measures when the system is pressureless.
•
Use pressure-resistant installation material only.
•
The feed pipe must be tubed firmly.
Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
•
Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 63 /Beko Technische Dokumentation/Sicherheit/Gefahr Netzspannung 1 s/w @ 0\mod_1184148186948_2901.docx @ 5796 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 64 /Beko Technische Dokumentation/Sicherheit/Maßnahmen Netzspannung BM 31U/32U/33U @ 7\mod_1390467197804_2901.docx @ 38043 @ @ 1
Measures:
•
During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•
When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
•
The removed control unit has no IP degree of protection.
•
All types of electrical works must be carried out by authorised and qualified personnel only.
Pos: 65 /Beko Technische Dokumentation/Sicherheit/Vorsicht Fehlfunktion @ 0\mod_1214378096290_2901.docx @ 9360 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 66 /Beko Technische Dokumentation/Sicherheit/Maßnahmen Fehlfunktionen BM @ 0\mod_1214378434025_2901.docx @ 9379 @ @ 1
r
Measures:
•
Condensate drainage which is reliable in performance directly optimises the compressed-air quality.
•
To prevent damage and breakdowns, it is imperative to observe the following:
•
Exact compliance with the specifications of use and with the performance parameters of
the BEKOMAT
•
Exact compliance with the installation- and operation instructions in this manual
•
Regular maintenance and control of the BEKOMAT
in this operating manual
Pos: 67 /---- Seitenumbruch ---- @ 0\mod_1157028099015_0.docx @ 2903 @ @ 1
BEKOMAT® 33U / 33U CO
®
.
®
, in connection with the case of application (see "Proper use" section)
Inspection and maintenance
®
in accordance with the instructions
21