5

Technical data

Pos: 26 /Beko Technische Dokumentation/Technische Daten/BEKOMAT/Techn. Daten BM 3xU + UC + GOST +Fcc (o.Leistg.) @ 5\mod_1358843578945_2901.docx @ 30450 @ @ 1
min./max. operating pressure
(see type plate)
min./max. temperature
(see type plate)
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, inclu-
ding a later version of the same standard incorporating the same level of testing requirements.
Pos: 27 /Beko Technische Dokumentation/Technische Daten/BEKOMAT/Leistung BM Standard @ 0\mod_1184050678383_2901.docx @ 5720 @ @ 1
Max. performance for the "blue" climate zone – see also Chapter "Climate zones and performance data"
max. compressor performance
max. refrig.-dryer performance
max. filter performance
Pos: 28 /---- Seitenumbruch ---- @ 0\mod_1157028099015_0.docx @ 2903 @ @ 1
BEKOMAT® 33U / 33U CO
0,8...16 bar (12...230 psi)
or
1,2...16 bar (17...230 psi)
+1...+60 °C (+34...+140 °F)
or
+1...+70 °C (+34...+158 °F)
3 x G ½ (NPT ½) internal
G ½ Ø 13 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
1.65 kg (3.63 lbs)
10 m³/min (350 scfm)
20 m³/min (700 scfm)
100 m³/min (3500 scfm)